Skip to main content

CVE-2025-40569: CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition') in Siemens RUGGEDCOM RST2428P

Medium
VulnerabilityCVE-2025-40569cvecve-2025-40569cwe-362
Published: Tue Jun 10 2025 (06/10/2025, 15:17:33 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: RUGGEDCOM RST2428P

Description

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XC316-8 (6GK5324-8TS00-2AC2) (All versions < V3.2), SCALANCE XC324-4 (6GK5328-4TS00-2AC2) (All versions < V3.2), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) (All versions < V3.2), SCALANCE XC332 (6GK5332-0GA00-2AC2) (All versions < V3.2), SCALANCE XC416-8 (6GK5424-8TR00-2AC2) (All versions < V3.2), SCALANCE XC424-4 (6GK5428-4TR00-2AC2) (All versions < V3.2), SCALANCE XC432 (6GK5432-0GR00-2AC2) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-2AR3) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-3AR3) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-4AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-2AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-3AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-4AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-2AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-3AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-4AR3) (All versions < V3.2), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-2AR3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-3AR3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-4AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-2AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-3AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-4AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-2AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-3AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-4AR3) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Configuration from Local PC" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.

AI-Powered Analysis

AILast updated: 07/10/2025, 20:04:02 UTC

Technical Analysis

CVE-2025-40569 is a medium-severity race condition vulnerability (CWE-362) affecting multiple Siemens industrial networking devices, specifically the RUGGEDCOM RST2428P and a broad range of SCALANCE switches (models XC316-8, XC324-4, XC332, XC416-8, XC424-4, XC432, XCH328, XCM324, XCM328, XCM332, XR302-32, XR322-12, XR326-8, XR502-32, XR522-12, XR526-8, XRH334, XRM334) with firmware versions prior to V3.2. The vulnerability resides in the "Load Configuration from Local PC" feature of the web interface, which suffers from improper synchronization during concurrent execution of shared resources. This race condition can be exploited by an authenticated remote attacker to cause the device to load a malicious configuration file instead of the legitimate one. However, exploitation requires that a legitimate administrator initiates the configuration load process, and the attacker must successfully win the race condition to replace the configuration. The vulnerability does not impact confidentiality but can compromise the integrity of device configurations, potentially allowing attackers to alter network behavior, disrupt industrial communications, or create persistent backdoors. The CVSS 3.1 base score is 4.8 (medium), reflecting the need for authentication, user interaction (admin action), and the complexity of winning the race condition. No known exploits are currently reported in the wild, and no patches have been linked yet, indicating the need for vigilance and proactive mitigation by affected organizations.

Potential Impact

For European organizations, especially those in critical infrastructure sectors such as energy, manufacturing, transportation, and utilities that rely on Siemens RUGGEDCOM and SCALANCE industrial networking equipment, this vulnerability poses a significant risk to operational integrity. Successful exploitation could allow attackers to inject malicious configurations, potentially disrupting industrial control systems, causing network outages, or enabling further lateral movement within industrial networks. Given the widespread use of Siemens industrial networking products across Europe, the impact could extend to national critical infrastructure, leading to economic losses, safety hazards, and regulatory non-compliance. The requirement for authenticated access and admin interaction somewhat limits the attack surface but insider threats or compromised credentials could facilitate exploitation. The integrity compromise could also undermine trust in network communications and control processes, affecting industrial automation reliability.

Mitigation Recommendations

1. Immediate mitigation should focus on restricting access to the web interface to trusted administrators only, using network segmentation and strict access control lists (ACLs) to limit exposure. 2. Implement multi-factor authentication (MFA) for all administrative access to reduce the risk of credential compromise. 3. Monitor administrative activities closely for unusual or unexpected configuration load attempts, enabling rapid detection of potential exploitation attempts. 4. Coordinate with Siemens for the release of firmware updates addressing this race condition and plan prompt patch deployment once available. 5. Until patches are available, consider disabling or restricting the "Load Configuration from Local PC" functionality if operationally feasible. 6. Conduct regular audits of device configurations to detect unauthorized changes. 7. Employ network intrusion detection systems (NIDS) tuned to detect anomalous configuration upload patterns or web interface misuse. 8. Train administrators on secure operational procedures and the risks associated with concurrent configuration changes to minimize inadvertent exploitation opportunities.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2025-04-16T08:20:17.031Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 68487f501b0bd07c39389a73

Added to database: 6/10/2025, 6:54:08 PM

Last enriched: 7/10/2025, 8:04:02 PM

Last updated: 8/13/2025, 8:59:31 AM