Skip to main content

CVE-2025-40583: CWE-319: Cleartext Transmission of Sensitive Information in Siemens SCALANCE LPE9403

Medium
VulnerabilityCVE-2025-40583cvecve-2025-40583cwe-319
Published: Tue May 13 2025 (05/13/2025, 09:39:11 UTC)
Source: CVE
Vendor/Project: Siemens
Product: SCALANCE LPE9403

Description

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions with SINEMA Remote Connect Edge Client installed). Affected devices do transmit sensitive information in cleartext. This could allow a privileged local attacker to retrieve this sensitive information.

AI-Powered Analysis

AILast updated: 07/12/2025, 02:17:50 UTC

Technical Analysis

CVE-2025-40583 is a vulnerability identified in the Siemens SCALANCE LPE9403 device, specifically affecting all versions with the SINEMA Remote Connect Edge Client installed. The core issue is the cleartext transmission of sensitive information, which violates secure communication principles and exposes critical data to potential interception. The vulnerability is categorized under CWE-319, which relates to the cleartext transmission of sensitive information. This means that sensitive data such as authentication tokens, session keys, or configuration details could be transmitted over the network without encryption or adequate protection. The vulnerability requires a privileged local attacker, indicating that the attacker must have some level of authorized access to the device or network segment where the device operates. The CVSS v3.1 base score is 4.4 (medium severity), with the vector AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N. This translates to an attack vector limited to local access, low attack complexity, high privileges required, no user interaction needed, unchanged scope, high impact on confidentiality, and no impact on integrity or availability. The vulnerability does not appear to have any known exploits in the wild at the time of publication, and no patches or mitigations have been officially released yet. Siemens SCALANCE LPE9403 devices are industrial network components used in critical infrastructure and industrial automation environments, often deployed in operational technology (OT) networks. The SINEMA Remote Connect Edge Client is used for secure remote access and management of these devices, making the confidentiality of transmitted data paramount. The vulnerability could allow an attacker with privileged local access to intercept sensitive information, potentially enabling further attacks such as credential theft, unauthorized access, or network reconnaissance. Given the nature of the device and its deployment in critical infrastructure, the exposure of sensitive information could have significant operational and security implications.

Potential Impact

For European organizations, especially those operating in industrial sectors such as manufacturing, energy, transportation, and utilities, this vulnerability poses a risk to the confidentiality of sensitive operational data. The cleartext transmission of sensitive information could lead to unauthorized disclosure of credentials or configuration details, which in turn could facilitate lateral movement within OT networks or enable attackers to compromise additional systems. This is particularly concerning for organizations that rely on Siemens SCALANCE LPE9403 devices for secure remote access and network segmentation. The potential impact includes increased risk of espionage, sabotage, or disruption of critical industrial processes. Although the vulnerability does not directly affect system integrity or availability, the compromise of confidentiality can indirectly lead to more severe attacks. European organizations with stringent regulatory requirements around data protection and critical infrastructure security may face compliance risks if such vulnerabilities are exploited. Additionally, the requirement for privileged local access limits the attack surface but does not eliminate risk, as insider threats or attackers who have already gained a foothold could exploit this vulnerability to escalate their capabilities.

Mitigation Recommendations

1. Restrict and monitor privileged local access to SCALANCE LPE9403 devices rigorously, ensuring that only authorized personnel can access these systems. 2. Implement network segmentation to isolate SCALANCE devices and limit exposure to potentially compromised network segments. 3. Use additional encryption layers such as VPN tunnels or IPsec to protect data in transit, compensating for the lack of encryption in the vulnerable component. 4. Monitor network traffic for unencrypted sensitive data transmissions and anomalous activity around SCALANCE devices. 5. Apply strict access control policies and multi-factor authentication for accessing management interfaces and remote clients. 6. Engage with Siemens for updates or patches addressing this vulnerability and plan for timely deployment once available. 7. Conduct regular security audits and vulnerability assessments focused on OT environments to detect and remediate similar issues proactively. 8. Train staff on the risks associated with privileged access and the importance of safeguarding credentials and devices in OT networks.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2025-04-16T08:20:17.033Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d9816c4522896dcbd6655

Added to database: 5/21/2025, 9:08:38 AM

Last enriched: 7/12/2025, 2:17:50 AM

Last updated: 7/30/2025, 10:38:56 PM

Views: 13

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats