CVE-2025-40593: CWE-20: Improper Input Validation in Siemens SIMATIC CN 4100
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition.
AI Analysis
Technical Summary
CVE-2025-40593 is a medium severity vulnerability affecting Siemens SIMATIC CN 4100 devices with firmware versions prior to V4.0. The root cause is improper input validation (CWE-20) in the device's handling of files stored in its SFTP folder. Specifically, the affected application allows an attacker with at least low-level privileges (PR:L) to store arbitrary files via the network (AV:N) without requiring user interaction (UI:N). This improper validation can be exploited to cause a denial of service (DoS) condition, impacting the device's availability. The vulnerability does not affect confidentiality or integrity directly but can disrupt operations by rendering the device unavailable or unstable. The CVSS 3.1 base score is 6.5, reflecting a medium severity level, with the attack vector being network-based, low attack complexity, and requiring some privileges but no user interaction. No known exploits are currently reported in the wild, and no patches have been linked yet. Siemens SIMATIC CN 4100 is an industrial communication device commonly used in automation environments to connect controllers and networks, making availability critical for industrial processes.
Potential Impact
For European organizations, especially those in industrial sectors such as manufacturing, energy, and utilities, this vulnerability poses a significant risk to operational continuity. The SIMATIC CN 4100 is used to facilitate communication in industrial control systems (ICS), and a denial of service could halt critical automation processes, leading to production downtime, safety risks, and financial losses. Given the increasing reliance on industrial automation in Europe, disruption of these devices could impact supply chains and critical infrastructure. While the vulnerability does not allow data theft or manipulation, the loss of availability in industrial environments can have cascading effects, including safety hazards and regulatory non-compliance. Organizations with Siemens automation equipment should consider this vulnerability a priority for risk management to maintain operational resilience.
Mitigation Recommendations
To mitigate this vulnerability, European organizations should: 1) Immediately identify all Siemens SIMATIC CN 4100 devices in their network and verify firmware versions; 2) Apply firmware updates or patches from Siemens as soon as they become available, since no patch is currently linked, organizations should monitor Siemens advisories closely; 3) Restrict network access to the SFTP service on these devices by implementing network segmentation and firewall rules to limit access only to trusted hosts and administrators; 4) Enforce strict access controls and monitor user privileges to ensure only authorized personnel can upload files to the device; 5) Implement anomaly detection and logging on the SFTP service to detect unusual file uploads or access patterns that could indicate exploitation attempts; 6) Consider deploying intrusion prevention systems (IPS) that can detect and block suspicious SFTP traffic targeting these devices; 7) Develop and test incident response plans specifically for industrial device availability issues to minimize downtime in case of exploitation.
Affected Countries
Germany, France, Italy, United Kingdom, Netherlands, Belgium, Poland, Spain, Sweden, Czech Republic
CVE-2025-40593: CWE-20: Improper Input Validation in Siemens SIMATIC CN 4100
Description
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition.
AI-Powered Analysis
Technical Analysis
CVE-2025-40593 is a medium severity vulnerability affecting Siemens SIMATIC CN 4100 devices with firmware versions prior to V4.0. The root cause is improper input validation (CWE-20) in the device's handling of files stored in its SFTP folder. Specifically, the affected application allows an attacker with at least low-level privileges (PR:L) to store arbitrary files via the network (AV:N) without requiring user interaction (UI:N). This improper validation can be exploited to cause a denial of service (DoS) condition, impacting the device's availability. The vulnerability does not affect confidentiality or integrity directly but can disrupt operations by rendering the device unavailable or unstable. The CVSS 3.1 base score is 6.5, reflecting a medium severity level, with the attack vector being network-based, low attack complexity, and requiring some privileges but no user interaction. No known exploits are currently reported in the wild, and no patches have been linked yet. Siemens SIMATIC CN 4100 is an industrial communication device commonly used in automation environments to connect controllers and networks, making availability critical for industrial processes.
Potential Impact
For European organizations, especially those in industrial sectors such as manufacturing, energy, and utilities, this vulnerability poses a significant risk to operational continuity. The SIMATIC CN 4100 is used to facilitate communication in industrial control systems (ICS), and a denial of service could halt critical automation processes, leading to production downtime, safety risks, and financial losses. Given the increasing reliance on industrial automation in Europe, disruption of these devices could impact supply chains and critical infrastructure. While the vulnerability does not allow data theft or manipulation, the loss of availability in industrial environments can have cascading effects, including safety hazards and regulatory non-compliance. Organizations with Siemens automation equipment should consider this vulnerability a priority for risk management to maintain operational resilience.
Mitigation Recommendations
To mitigate this vulnerability, European organizations should: 1) Immediately identify all Siemens SIMATIC CN 4100 devices in their network and verify firmware versions; 2) Apply firmware updates or patches from Siemens as soon as they become available, since no patch is currently linked, organizations should monitor Siemens advisories closely; 3) Restrict network access to the SFTP service on these devices by implementing network segmentation and firewall rules to limit access only to trusted hosts and administrators; 4) Enforce strict access controls and monitor user privileges to ensure only authorized personnel can upload files to the device; 5) Implement anomaly detection and logging on the SFTP service to detect unusual file uploads or access patterns that could indicate exploitation attempts; 6) Consider deploying intrusion prevention systems (IPS) that can detect and block suspicious SFTP traffic targeting these devices; 7) Develop and test incident response plans specifically for industrial device availability issues to minimize downtime in case of exploitation.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- siemens
- Date Reserved
- 2025-04-16T08:20:17.034Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 686cf5646f40f0eb72f3f5ff
Added to database: 7/8/2025, 10:39:32 AM
Last enriched: 7/8/2025, 10:57:18 AM
Last updated: 8/18/2025, 11:28:28 PM
Views: 13
Related Threats
CVE-2025-55455: n/a
HighCVE-2025-8193
UnknownCVE-2025-9356: Stack-based Buffer Overflow in Linksys RE6250
HighCVE-2025-9355: Stack-based Buffer Overflow in Linksys RE6250
HighCVE-2025-43761: CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') in Liferay Portal
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.