CVE-2025-46737: CWE-346 Origin Validation Error in Schweitzer Engineering Laboratories SEL-5037 Grid Configurator
SEL-5037 Grid Configurator contains an overly permissive Cross Origin Resource Sharing (CORS) configuration for a data gateway service in the application. This gateway service includes an API which is not properly configured to reject requests from unexpected sources.
AI Analysis
Technical Summary
CVE-2025-46737 is a high-severity vulnerability identified in the Schweitzer Engineering Laboratories (SEL) SEL-5037 Grid Configurator, a specialized software product used for configuring and managing electrical grid infrastructure. The vulnerability stems from an overly permissive Cross-Origin Resource Sharing (CORS) configuration in a data gateway service within the application. Specifically, the API exposed by this gateway service does not properly validate the origin of incoming requests, allowing requests from unauthorized or unexpected sources. This misconfiguration corresponds to CWE-346: Origin Validation Error, which occurs when an application fails to correctly verify the origin of requests, potentially enabling cross-origin attacks. The vulnerability has a CVSS 3.1 base score of 7.4, indicating high severity. The vector string (AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N) reveals that the attack can be performed remotely over the network without privileges, requires low attack complexity, and only requires user interaction. The impact is primarily on integrity, with no direct confidentiality or availability loss. The scope is changed, meaning the vulnerability can affect resources beyond the vulnerable component. Although no known exploits are currently reported in the wild, the vulnerability poses a significant risk because an attacker could leverage the lax CORS policy to perform unauthorized actions on behalf of authenticated users by tricking them into visiting malicious web pages. This could lead to unauthorized manipulation of grid configuration data, potentially disrupting grid operations or causing misconfigurations. Given the critical role of SEL-5037 in electrical grid management, exploitation could have serious operational consequences.
Potential Impact
For European organizations, especially those involved in critical infrastructure such as electrical grid management and utilities, this vulnerability presents a substantial risk. The SEL-5037 Grid Configurator is used to manage grid configurations, and unauthorized integrity modifications could lead to incorrect grid settings, potentially causing outages, equipment damage, or cascading failures. The impact on integrity without direct confidentiality or availability loss means attackers could manipulate data or commands without detection, undermining trust in grid operations. European utilities and grid operators are often subject to stringent regulatory requirements for cybersecurity and operational resilience, so exploitation could also lead to regulatory penalties and reputational damage. The cross-origin nature of the vulnerability means that attackers could exploit it via social engineering, targeting employees or contractors with access to the system. Given the interconnected nature of European power grids, a successful attack in one country could have broader regional implications, affecting energy supply stability.
Mitigation Recommendations
To mitigate this vulnerability, European organizations using the SEL-5037 Grid Configurator should: 1) Immediately review and restrict the CORS policy on the data gateway service to only allow trusted, specific origins that require access, avoiding wildcard or overly broad origin allowances. 2) Implement strict server-side origin validation to reject requests from unauthorized domains, ensuring that the API only processes requests from legitimate sources. 3) Apply network segmentation and access controls to limit exposure of the grid configurator interfaces to trusted internal networks and VPNs, reducing the attack surface. 4) Conduct user awareness training to reduce the risk of social engineering attacks that could trigger cross-origin exploits. 5) Monitor logs and network traffic for unusual cross-origin requests or API usage patterns indicative of exploitation attempts. 6) Engage with Schweitzer Engineering Laboratories for patches or updates addressing this vulnerability and apply them promptly once available. 7) Consider deploying Web Application Firewalls (WAFs) with custom rules to detect and block suspicious cross-origin requests targeting the vulnerable API endpoints. These steps go beyond generic advice by focusing on configuration hardening, network controls, and proactive monitoring tailored to the specific nature of the vulnerability and the critical infrastructure context.
Affected Countries
Germany, France, United Kingdom, Italy, Spain, Netherlands, Belgium, Poland, Sweden, Czech Republic
CVE-2025-46737: CWE-346 Origin Validation Error in Schweitzer Engineering Laboratories SEL-5037 Grid Configurator
Description
SEL-5037 Grid Configurator contains an overly permissive Cross Origin Resource Sharing (CORS) configuration for a data gateway service in the application. This gateway service includes an API which is not properly configured to reject requests from unexpected sources.
AI-Powered Analysis
Technical Analysis
CVE-2025-46737 is a high-severity vulnerability identified in the Schweitzer Engineering Laboratories (SEL) SEL-5037 Grid Configurator, a specialized software product used for configuring and managing electrical grid infrastructure. The vulnerability stems from an overly permissive Cross-Origin Resource Sharing (CORS) configuration in a data gateway service within the application. Specifically, the API exposed by this gateway service does not properly validate the origin of incoming requests, allowing requests from unauthorized or unexpected sources. This misconfiguration corresponds to CWE-346: Origin Validation Error, which occurs when an application fails to correctly verify the origin of requests, potentially enabling cross-origin attacks. The vulnerability has a CVSS 3.1 base score of 7.4, indicating high severity. The vector string (AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N) reveals that the attack can be performed remotely over the network without privileges, requires low attack complexity, and only requires user interaction. The impact is primarily on integrity, with no direct confidentiality or availability loss. The scope is changed, meaning the vulnerability can affect resources beyond the vulnerable component. Although no known exploits are currently reported in the wild, the vulnerability poses a significant risk because an attacker could leverage the lax CORS policy to perform unauthorized actions on behalf of authenticated users by tricking them into visiting malicious web pages. This could lead to unauthorized manipulation of grid configuration data, potentially disrupting grid operations or causing misconfigurations. Given the critical role of SEL-5037 in electrical grid management, exploitation could have serious operational consequences.
Potential Impact
For European organizations, especially those involved in critical infrastructure such as electrical grid management and utilities, this vulnerability presents a substantial risk. The SEL-5037 Grid Configurator is used to manage grid configurations, and unauthorized integrity modifications could lead to incorrect grid settings, potentially causing outages, equipment damage, or cascading failures. The impact on integrity without direct confidentiality or availability loss means attackers could manipulate data or commands without detection, undermining trust in grid operations. European utilities and grid operators are often subject to stringent regulatory requirements for cybersecurity and operational resilience, so exploitation could also lead to regulatory penalties and reputational damage. The cross-origin nature of the vulnerability means that attackers could exploit it via social engineering, targeting employees or contractors with access to the system. Given the interconnected nature of European power grids, a successful attack in one country could have broader regional implications, affecting energy supply stability.
Mitigation Recommendations
To mitigate this vulnerability, European organizations using the SEL-5037 Grid Configurator should: 1) Immediately review and restrict the CORS policy on the data gateway service to only allow trusted, specific origins that require access, avoiding wildcard or overly broad origin allowances. 2) Implement strict server-side origin validation to reject requests from unauthorized domains, ensuring that the API only processes requests from legitimate sources. 3) Apply network segmentation and access controls to limit exposure of the grid configurator interfaces to trusted internal networks and VPNs, reducing the attack surface. 4) Conduct user awareness training to reduce the risk of social engineering attacks that could trigger cross-origin exploits. 5) Monitor logs and network traffic for unusual cross-origin requests or API usage patterns indicative of exploitation attempts. 6) Engage with Schweitzer Engineering Laboratories for patches or updates addressing this vulnerability and apply them promptly once available. 7) Consider deploying Web Application Firewalls (WAFs) with custom rules to detect and block suspicious cross-origin requests targeting the vulnerable API endpoints. These steps go beyond generic advice by focusing on configuration hardening, network controls, and proactive monitoring tailored to the specific nature of the vulnerability and the critical infrastructure context.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- SEL
- Date Reserved
- 2025-04-28T21:27:38.847Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d9816c4522896dcbd6a58
Added to database: 5/21/2025, 9:08:38 AM
Last enriched: 7/12/2025, 3:17:08 AM
Last updated: 8/12/2025, 11:05:13 AM
Views: 19
Related Threats
CVE-2025-3495: CWE-338 Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) in Delta Electronics COMMGR
CriticalCVE-2025-53948: CWE-415 Double Free in Santesoft Sante PACS Server
HighCVE-2025-52584: CWE-122 Heap-based Buffer Overflow in Ashlar-Vellum Cobalt
HighCVE-2025-46269: CWE-122 Heap-based Buffer Overflow in Ashlar-Vellum Cobalt
HighCVE-2025-54862: CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') in Santesoft Sante PACS Server
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.