CVE-2025-47420: CWE-269 Improper Privilege Management in Crestron Automate VX
266 vulnerability in Crestron Automate VX allows Privilege Escalation.This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
AI Analysis
Technical Summary
CVE-2025-47420 is a high-severity vulnerability identified in Crestron Automate VX, a widely used automation platform for managing smart building and enterprise environments. The vulnerability is classified under CWE-269, which pertains to improper privilege management. Specifically, this flaw allows an attacker with limited privileges to escalate their privileges within the system without requiring user interaction or prior authentication. The affected versions range from 5.6.8161.21536 through 6.4.0.49. The CVSS 4.0 base score of 8.7 reflects the critical nature of this vulnerability, highlighting its network attack vector (AV:N), low attack complexity (AC:L), no required authentication (AT:N), and no user interaction (UI:N). The vulnerability impacts confidentiality, integrity, and availability at a high level, as it enables an attacker to gain elevated privileges, potentially leading to full system compromise, unauthorized access to sensitive automation controls, and disruption of critical building management functions. No known exploits are currently reported in the wild, but the ease of exploitation and the criticality of the affected systems make it a significant threat. Crestron Automate VX is often deployed in corporate, educational, healthcare, and government facilities to automate and control audiovisual, lighting, HVAC, and security systems, making the potential impact broad and severe.
Potential Impact
For European organizations, this vulnerability poses a substantial risk due to the widespread adoption of Crestron Automate VX in smart building and enterprise automation sectors. Successful exploitation could lead to unauthorized control over critical infrastructure components such as HVAC, lighting, and security systems, resulting in operational disruptions, safety hazards, and potential data breaches. The ability to escalate privileges without authentication increases the risk of insider threats and external attackers leveraging compromised low-privilege accounts. This could affect compliance with European data protection regulations like GDPR if personal or sensitive data managed via these systems is exposed or manipulated. Additionally, disruption of building automation could impact business continuity, especially in sectors reliant on tightly controlled environments such as healthcare and finance. The lack of known exploits in the wild provides a window for proactive mitigation, but the high severity score necessitates urgent attention.
Mitigation Recommendations
European organizations should immediately inventory their deployments of Crestron Automate VX to identify affected versions. Since no patch links are currently provided, organizations should engage directly with Crestron for official patches or updates addressing CVE-2025-47420. In the interim, implement strict network segmentation to isolate Crestron Automate VX systems from general enterprise networks and limit access to trusted administrators only. Employ robust monitoring and logging to detect unusual privilege escalation attempts or anomalous activities within the automation environment. Enforce the principle of least privilege rigorously, ensuring that users and services operate with minimal necessary permissions. Consider deploying application-layer firewalls or intrusion detection systems tailored to detect exploitation attempts targeting Crestron systems. Additionally, review and tighten authentication and access controls around these devices, even though the vulnerability does not require authentication, to reduce the attack surface. Regularly update incident response plans to include scenarios involving building automation compromise.
Affected Countries
Germany, United Kingdom, France, Netherlands, Sweden, Switzerland, Belgium, Italy
CVE-2025-47420: CWE-269 Improper Privilege Management in Crestron Automate VX
Description
266 vulnerability in Crestron Automate VX allows Privilege Escalation.This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
AI-Powered Analysis
Technical Analysis
CVE-2025-47420 is a high-severity vulnerability identified in Crestron Automate VX, a widely used automation platform for managing smart building and enterprise environments. The vulnerability is classified under CWE-269, which pertains to improper privilege management. Specifically, this flaw allows an attacker with limited privileges to escalate their privileges within the system without requiring user interaction or prior authentication. The affected versions range from 5.6.8161.21536 through 6.4.0.49. The CVSS 4.0 base score of 8.7 reflects the critical nature of this vulnerability, highlighting its network attack vector (AV:N), low attack complexity (AC:L), no required authentication (AT:N), and no user interaction (UI:N). The vulnerability impacts confidentiality, integrity, and availability at a high level, as it enables an attacker to gain elevated privileges, potentially leading to full system compromise, unauthorized access to sensitive automation controls, and disruption of critical building management functions. No known exploits are currently reported in the wild, but the ease of exploitation and the criticality of the affected systems make it a significant threat. Crestron Automate VX is often deployed in corporate, educational, healthcare, and government facilities to automate and control audiovisual, lighting, HVAC, and security systems, making the potential impact broad and severe.
Potential Impact
For European organizations, this vulnerability poses a substantial risk due to the widespread adoption of Crestron Automate VX in smart building and enterprise automation sectors. Successful exploitation could lead to unauthorized control over critical infrastructure components such as HVAC, lighting, and security systems, resulting in operational disruptions, safety hazards, and potential data breaches. The ability to escalate privileges without authentication increases the risk of insider threats and external attackers leveraging compromised low-privilege accounts. This could affect compliance with European data protection regulations like GDPR if personal or sensitive data managed via these systems is exposed or manipulated. Additionally, disruption of building automation could impact business continuity, especially in sectors reliant on tightly controlled environments such as healthcare and finance. The lack of known exploits in the wild provides a window for proactive mitigation, but the high severity score necessitates urgent attention.
Mitigation Recommendations
European organizations should immediately inventory their deployments of Crestron Automate VX to identify affected versions. Since no patch links are currently provided, organizations should engage directly with Crestron for official patches or updates addressing CVE-2025-47420. In the interim, implement strict network segmentation to isolate Crestron Automate VX systems from general enterprise networks and limit access to trusted administrators only. Employ robust monitoring and logging to detect unusual privilege escalation attempts or anomalous activities within the automation environment. Enforce the principle of least privilege rigorously, ensuring that users and services operate with minimal necessary permissions. Consider deploying application-layer firewalls or intrusion detection systems tailored to detect exploitation attempts targeting Crestron systems. Additionally, review and tighten authentication and access controls around these devices, even though the vulnerability does not require authentication, to reduce the attack surface. Regularly update incident response plans to include scenarios involving building automation compromise.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- Crestron
- Date Reserved
- 2025-05-06T19:36:18.441Z
- Cisa Enriched
- true
- Cvss Version
- 4.0
- State
- PUBLISHED
Threat ID: 682d981bc4522896dcbd9a0b
Added to database: 5/21/2025, 9:08:43 AM
Last enriched: 7/5/2025, 2:26:35 PM
Last updated: 8/11/2025, 9:48:22 PM
Views: 13
Related Threats
CVE-2025-53948: CWE-415 Double Free in Santesoft Sante PACS Server
HighCVE-2025-52584: CWE-122 Heap-based Buffer Overflow in Ashlar-Vellum Cobalt
HighCVE-2025-46269: CWE-122 Heap-based Buffer Overflow in Ashlar-Vellum Cobalt
HighCVE-2025-54862: CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') in Santesoft Sante PACS Server
MediumCVE-2025-54759: CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') in Santesoft Sante PACS Server
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.