Skip to main content
CVE-2025-52694VulnerabilityPublished Updated

CVE-2025-52694: Advantech IoTSuite and IoT Edge Products · SQL Injection

Affects Advantech IoTSuite and IoT Edge ProductsSource CVE Database V5

0

Not known to be exploited · public detection template (Nuclei) · 39% EPSS · CVSS 10.0 Critical.

Data as of 26 Oct 2026, 07:57 UTC

CVSS 3.1 base score
10.0Critical
How severe the flaw is on the 0–10 CVSS scale.
EPSS
39.9% chance of exploitation in 30 days – higher than 98% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 12 Jan 2026

  2. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  3. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  4. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.

What to do

Affected software

ProductAffectedFixed in
AdvantechIoTSuite and IoT Edge ProductsAffected
  • =SaaSComposer prior to version V3.4.15
  • =IoTSuite Growth Linux docker prior to version V2.0.2
  • =IoTSuite Starter Linux docker prior to version V2.0.2
  • =IoT Edge Linux docker prior to version V2.0.2
  • =IoT Edge Windows prior to version V2.0.2
  • =WebAccess/SCADA prior to version V9.2.2
  • =WebAccess SaaS-Composer prior to version 3.4.15.1
  • =ECOWatch SaaS-Composer prior to version 3.4.15
Fixed in–

AI-suggested

European organizations should immediately inventory their Advantech IoTSuite and IoT Edge product deployments to identify affected versions. They must prioritize upgrading to the latest patched versions: SaaSComposer to at least V3.4.15, IoTSuite Growth and Starter Linux dockers and IoT Edge (Linux and Windows) to at least V2.0.2, and WebAccess/SCADA to V9.2.2 or later. Until patches are applied, organizations should restrict internet exposure of these services by implementing network segmentation and firewall rules to limit access to trusted IPs only. Employ Web Application Firewalls (WAFs) with SQL injection detection and prevention capabilities to monitor and block suspicious queries. Conduct thorough input validation and sanitization on any custom integrations with these platforms. Regularly audit logs for anomalous database queries or unauthorized access attempts. Additionally, implement strong monitoring and incident response plans tailored to IoT and OT environments. Collaborate with Advantech support channels for timely patch releases and guidance. Finally, raise awareness among operational teams about the risks of exposing IoT management interfaces publicly.

Description

Successful exploitation of the SQL injection vulnerability could allow an unauthenticated remote attacker to execute arbitrary SQL commands on the vulnerable service when it is exposed to the Internet, potentially affecting data confidentiality, integrity, and availability. Users and administrators of affected product versions are advised to update to the latest versions immediately.

References

Community reviews

Loading reviews…