CVE-2025-55050: CWE-1242 in Baicells NOVA430e/430i, NOVA436Q, NEUTRINO430, NOVA846

0
Critical
VulnerabilityCVE-2025-55050cvecve-2025-55050cwe-1242
Published: Tue Sep 09 2025 (09/09/2025, 18:56:59 UTC)
Source: CVE Database V5
Vendor/Project: Baicells
Product: NOVA430e/430i, NOVA436Q, NEUTRINO430, NOVA846

Description

CWE-1242: Inclusion of Undocumented Features

AI-Powered Analysis

AILast updated: 09/17/2025, 01:02:54 UTC

Technical Analysis

CVE-2025-55050 is a critical security vulnerability identified in multiple Baicells products, including the NOVA430e/430i, NOVA436Q, NEUTRINO430, and NOVA846 models. The vulnerability is classified under CWE-1242, which pertains to the inclusion of undocumented features within software or hardware products. These undocumented features can introduce hidden functionalities or backdoors that are not disclosed to users or administrators, potentially allowing unauthorized access or control. The affected versions include BaiBLQ_3.0.12 and older, as well as BaiBU_DNB4_2.4.9 and older. The CVSS v3.1 base score is 9.8, indicating a critical severity level. The vector string (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) reveals that the vulnerability is remotely exploitable over the network without requiring any privileges or user interaction, and it impacts confidentiality, integrity, and availability to a high degree. The lack of available patches at the time of publication increases the urgency for mitigation. Baicells products are typically used in wireless broadband infrastructure, including LTE and 5G small cell deployments, which are critical components in telecommunications networks. Exploitation of this vulnerability could allow attackers to leverage undocumented features to gain unauthorized access, manipulate data, disrupt services, or potentially pivot within the network, severely compromising network security and service reliability.

Potential Impact

For European organizations, especially telecommunications providers and enterprises relying on Baicells infrastructure, this vulnerability poses a significant risk. Exploitation could lead to unauthorized access to network equipment, resulting in data breaches, service outages, and potential disruption of critical communications services. Given the role of Baicells devices in wireless broadband and private LTE/5G networks, the impact extends to sectors such as public safety, transportation, manufacturing, and smart city deployments that depend on reliable and secure connectivity. The high severity and ease of exploitation mean attackers could rapidly compromise affected systems, potentially leading to widespread service degradation or espionage activities. Additionally, the absence of known exploits in the wild currently does not diminish the threat, as the vulnerability is publicly disclosed and could be targeted by advanced persistent threat (APT) groups or cybercriminals. European organizations must consider the regulatory implications of such breaches under GDPR, which mandates strict data protection and breach notification requirements.

Mitigation Recommendations

Immediate mitigation steps include conducting a thorough inventory of Baicells devices in use and identifying those running affected firmware versions (BaiBLQ_3.0.12 and older, BaiBU_DNB4_2.4.9 and older). Organizations should engage with Baicells support channels to obtain information on patches or firmware updates addressing CVE-2025-55050 and prioritize their deployment. In the absence of official patches, network segmentation should be enforced to isolate vulnerable devices from critical infrastructure and limit exposure to untrusted networks. Implement strict access controls and monitoring on management interfaces of Baicells devices, including the use of VPNs, strong authentication mechanisms, and logging to detect anomalous activities. Regularly update intrusion detection and prevention systems with signatures or heuristics related to this vulnerability. Additionally, consider deploying network-level protections such as firewall rules to restrict traffic to and from affected devices. Organizations should also prepare incident response plans specific to telecommunications infrastructure compromise and conduct security awareness training for network administrators regarding this vulnerability.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
INCD
Date Reserved
2025-08-06T11:04:25.088Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 68c079872c3c95605bcf75c5

Added to database: 9/9/2025, 7:01:27 PM

Last enriched: 9/17/2025, 1:02:54 AM

Last updated: 10/30/2025, 4:13:06 PM

Views: 41

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats