Skip to main content
CVE-2025-57786VulnerabilityPublished Updated

CVE-2025-57786: MedDream PACS Premium · Cross-site Scripting

Affects MedDream PACS PremiumSource CVE Database V5

0

Not known to be exploited · CVSS 6.1 Medium.

Data as of 25 Oct 2026, 19:02 UTC

CVSS 3.1 base score
6.1Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.3% chance of exploitation in 30 days – higher than 29% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 20 Jan 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-25.

What to do

Affected software

ProductAffectedFixed in
MedDreamMedDream PACS PremiumAffected
  • =7.3.6.870
Fixed in–

AI-suggested

1. Monitor MedDream vendor communications closely for official patches addressing CVE-2025-57786 and apply them promptly once available. 2. Implement web application firewall (WAF) rules to detect and block suspicious input patterns targeting the notifynewstudy functionality, focusing on script injection attempts. 3. Employ strict input validation and output encoding on all user-controllable inputs within the PACS web interface to neutralize potentially malicious scripts. 4. Conduct user awareness training for healthcare staff to recognize and avoid clicking on suspicious or unsolicited URLs, especially those purporting to relate to medical imaging studies. 5. Restrict access to the PACS web interface to trusted networks or VPNs to reduce exposure to external attackers. 6. Enable Content Security Policy (CSP) headers on the PACS web server to limit the execution of unauthorized scripts. 7. Regularly audit and monitor web server logs for unusual URL access patterns indicative of attempted XSS exploitation. 8. Consider deploying browser security extensions or endpoint protections that can mitigate the impact of reflected XSS attacks. These targeted measures go beyond generic advice by focusing on the specific vulnerable functionality and the healthcare operational context.

Description

CVE-2025-57786 is a reflected cross-site scripting (XSS) vulnerability in MedDream PACS Premium version 7.3.6.870, specifically in the notifynewstudy functionality. An attacker can craft a malicious URL that, when visited by a user, executes arbitrary JavaScript code in the context of the victim's browser. This vulnerability requires user interaction, such as clicking a malicious link, and does not require authentication. The CVSS score is 6.1 (medium severity) due to its potential to compromise confidentiality and integrity but not availability. No known exploits are currently reported in the wild. European healthcare organizations using this PACS software are at risk, particularly in countries with significant MedDream deployments.

References

Community reviews