Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2025-64307: CWE-306 in Brightpick AI Brightpick Mission Control / Internal Logic Control

0
Medium
VulnerabilityCVE-2025-64307cvecve-2025-64307cwe-306
Published: Fri Nov 14 2025 (11/14/2025, 23:34:59 UTC)
Source: CVE Database V5
Vendor/Project: Brightpick AI
Product: Brightpick Mission Control / Internal Logic Control

Description

The Brightpick Internal Logic Control web interface is accessible without requiring user authentication. An unauthorized user could exploit this interface to manipulate robot control functions, including initiating or halting runners, assigning jobs, clearing stations, and deploying storage totes.

AI-Powered Analysis

AILast updated: 11/14/2025, 23:43:33 UTC

Technical Analysis

CVE-2025-64307 identifies a critical security weakness in the Brightpick Mission Control / Internal Logic Control web interface developed by Brightpick AI. The core issue is the absence of any authentication mechanism, allowing any unauthorized user with network access to the interface to control robotic operations. This includes initiating or halting robotic runners, assigning operational jobs, clearing stations, and deploying storage totes, which are essential functions in automated warehouse and logistics environments. The vulnerability is classified under CWE-306 (Missing Authentication for Critical Function) and affects all versions of the product. The CVSS v3.1 score is 6.5 (medium severity), reflecting the lack of confidentiality impact but high integrity impact. The attack vector is adjacent network (AV:A), requiring no privileges (PR:N) or user interaction (UI:N), and the scope remains unchanged (S:U). No patches or exploits are currently known, but the risk lies in potential operational disruption, manipulation of inventory handling, and possible cascading effects on supply chain reliability. The vulnerability highlights a critical design flaw where critical control interfaces are exposed without authentication, violating fundamental security principles for industrial control systems and robotics management platforms.

Potential Impact

For European organizations, particularly those in logistics, warehousing, and manufacturing sectors that deploy Brightpick AI robotic automation solutions, this vulnerability poses a significant risk to operational integrity. Unauthorized manipulation of robotic controls can lead to halted operations, misrouted or lost inventory, physical damage to goods or equipment, and safety hazards for personnel. Disruption in automated supply chains can cause delays, financial losses, and reputational damage. Given the increasing reliance on automation in European industries, exploitation could affect critical infrastructure and commercial operations. While confidentiality is not directly impacted, the integrity and availability of robotic processes are at risk, potentially causing cascading operational failures. The lack of authentication also raises concerns about insider threats or lateral movement by attackers who gain network access. The medium severity rating may underestimate the real-world operational impact in highly automated environments.

Mitigation Recommendations

To mitigate CVE-2025-64307, European organizations should implement the following specific measures: 1) Immediately restrict network access to the Brightpick Mission Control / Internal Logic Control interface using network segmentation and firewall rules, limiting it to trusted management networks only. 2) Deploy VPNs or zero-trust network access solutions to enforce strong authentication before any access to the control interface is permitted. 3) Monitor network traffic and logs for unauthorized access attempts or anomalous commands targeting robotic control functions. 4) Engage with Brightpick AI for any available updates or patches and request a timeline for authentication enforcement. 5) Implement compensating controls such as multi-factor authentication proxies or reverse proxies that add authentication layers in front of the vulnerable interface. 6) Conduct regular security audits and penetration tests focusing on industrial control systems and robotic automation interfaces. 7) Train operational staff to recognize signs of robotic manipulation and establish incident response plans specific to automated system disruptions. These steps go beyond generic advice by focusing on network-level controls and compensating authentication mechanisms until a vendor patch is available.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.2
Assigner Short Name
icscert
Date Reserved
2025-10-29T17:40:55.207Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6917bd92ed59478372471172

Added to database: 11/14/2025, 11:38:58 PM

Last enriched: 11/14/2025, 11:43:33 PM

Last updated: 11/17/2025, 1:46:04 AM

Views: 18

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.