Skip to main content
CVE-2025-9585VulnerabilityPublished

CVE-2025-9585: Comfast CF-N1 · Command Injection

Affects Comfast CF-N1Source CVE Database V5

0

Not known to be exploited · CVSS 5.3 Medium.

Data as of 25 Oct 2026, 19:02 UTC

CVSS 4.0 base score
5.3Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
4.6% chance of exploitation in 30 days – higher than 91% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 28 Aug 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-25.

What to do

Affected software

ProductAffectedFixed in
Comfast CF-N1Affected
  • =2.6.0
Fixed in–

AI-suggested

1. Immediate mitigation should include isolating Comfast CF-N1 devices from untrusted networks and restricting management interfaces to trusted administrative networks only. 2. Network segmentation should be enforced to limit the impact of a compromised device. 3. Monitor network traffic for unusual command execution patterns or unexpected outbound connections originating from these devices. 4. Apply any available firmware updates or patches from Comfast as soon as they are released; if no patches are currently available, engage with the vendor for timelines and possible workarounds. 5. Implement strict access controls and change default credentials to strong, unique passwords to reduce privilege escalation risks. 6. Consider deploying intrusion detection/prevention systems (IDS/IPS) with signatures targeting command injection attempts on the affected endpoint. 7. Conduct regular security audits and vulnerability scans focusing on network devices to identify and remediate similar issues proactively. 8. Educate network administrators about this vulnerability and ensure they follow best practices for device hardening and monitoring.

Description

A vulnerability was determined in Comfast CF-N1 2.6.0. This affects the function wifilith_delete_pic_file of the file /usr/bin/webmgnt. This manipulation of the argument portal_delete_picname causes command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

References

Community reviews

Loading reviews…