Skip to main content

CVE-2025-9771: SQL Injection in SourceCodester Eye Clinic Management System

Medium
VulnerabilityCVE-2025-9771cvecve-2025-9771
Published: Mon Sep 01 2025 (09/01/2025, 09:02:07 UTC)
Source: CVE Database V5
Vendor/Project: SourceCodester
Product: Eye Clinic Management System

Description

A security vulnerability has been detected in SourceCodester Eye Clinic Management System 1.0. Affected by this issue is some unknown functionality of the file /main/search_index_Diagnosis.php. Such manipulation of the argument Search leads to sql injection. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used.

AI-Powered Analysis

AILast updated: 09/01/2025, 09:32:44 UTC

Technical Analysis

CVE-2025-9771 is a SQL Injection vulnerability identified in version 1.0 of the SourceCodester Eye Clinic Management System, specifically in the /main/search_index_Diagnosis.php file. The vulnerability arises from improper sanitization or validation of the 'Search' parameter, which is used in SQL queries. An attacker can remotely manipulate this parameter to inject malicious SQL code, potentially allowing unauthorized access to the backend database. This can lead to unauthorized data disclosure, data modification, or even deletion, depending on the database permissions and the nature of the injected payload. The vulnerability requires no authentication or user interaction, making it exploitable by any remote attacker with network access to the affected system. The CVSS v4.0 score is 6.9 (medium severity), reflecting the ease of exploitation (network vector, low attack complexity, no privileges or user interaction required) but limited impact on confidentiality, integrity, and availability (each rated low). No known exploits are currently observed in the wild, but public disclosure of the exploit code increases the risk of exploitation. The vulnerability affects a critical component of the Eye Clinic Management System that handles diagnosis search functionality, which likely interacts with sensitive patient medical data, increasing the potential impact of data breaches or manipulation.

Potential Impact

For European organizations using the SourceCodester Eye Clinic Management System version 1.0, this vulnerability poses a significant risk to patient data confidentiality and integrity. Exploitation could lead to unauthorized access to sensitive medical records, violating GDPR requirements and potentially resulting in legal and financial penalties. Data manipulation could also affect clinical decision-making, compromising patient safety. The availability impact is limited but could occur if attackers execute destructive SQL commands. Given the healthcare sector's critical nature and strict regulatory environment in Europe, even a medium-severity vulnerability like this demands prompt attention. Organizations may face reputational damage and loss of patient trust if exploited. Furthermore, the remote and unauthenticated nature of the vulnerability increases the attack surface, especially for clinics with internet-facing management systems or insufficient network segmentation.

Mitigation Recommendations

1. Immediate application of patches or updates from the vendor once available is the most effective mitigation. Since no patch links are currently provided, organizations should monitor vendor communications closely. 2. Implement Web Application Firewalls (WAFs) with rules to detect and block SQL injection attempts targeting the 'Search' parameter in /main/search_index_Diagnosis.php. 3. Conduct input validation and sanitization on all user-supplied data, especially the 'Search' parameter, using parameterized queries or prepared statements to prevent injection. 4. Restrict database user permissions to the minimum necessary to limit the impact of any successful injection. 5. Network segmentation should be enforced to isolate the Eye Clinic Management System from the public internet or untrusted networks, reducing exposure. 6. Regularly audit and monitor logs for suspicious query patterns or anomalies indicative of SQL injection attempts. 7. Educate IT staff and administrators about the vulnerability and encourage proactive vulnerability management practices. 8. If immediate patching is not possible, consider disabling or restricting access to the vulnerable search functionality as a temporary workaround.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
VulDB
Date Reserved
2025-08-31T17:18:57.310Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 68b564b3ad5a09ad00cc4d1b

Added to database: 9/1/2025, 9:17:39 AM

Last enriched: 9/1/2025, 9:32:44 AM

Last updated: 9/1/2025, 10:13:20 AM