Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2026-22913: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in SICK AG TDC-X401GL

0
Medium
VulnerabilityCVE-2026-22913cvecve-2026-22913cwe-79
Published: Thu Jan 15 2026 (01/15/2026, 13:05:40 UTC)
Source: CVE Database V5
Vendor/Project: SICK AG
Product: TDC-X401GL

Description

Improper handling of a URL parameter may allow attackers to execute code in a user's browser after login. This can lead to the extraction of sensitive data.

AI-Powered Analysis

AILast updated: 01/15/2026, 13:35:42 UTC

Technical Analysis

CVE-2026-22913 is a cross-site scripting (XSS) vulnerability identified in the SICK AG TDC-X401GL device, a product commonly used in industrial automation environments. The vulnerability stems from improper neutralization of user-supplied input in a URL parameter during web page generation. Specifically, the device's web interface fails to adequately sanitize or encode this input, allowing an attacker to inject malicious JavaScript code that executes in the context of a logged-in user's browser session. This flaw does not require prior authentication or elevated privileges but does require the victim to interact with a crafted URL, typically by clicking a malicious link. Once exploited, the attacker can execute arbitrary scripts, potentially leading to the extraction of sensitive information such as session tokens, configuration data, or other confidential details accessible through the web interface. The vulnerability has a CVSS v3.1 base score of 4.3, indicating a medium severity level. The attack vector is network-based with low attack complexity and no privileges required, but user interaction is necessary. There is no impact on integrity or availability, and no known exploits have been reported in the wild. No patches or fixes have been published at this time, suggesting that affected organizations must implement interim mitigations. Given the device's role in industrial control systems, exploitation could indirectly affect operational processes if sensitive data is compromised or if attackers leverage stolen credentials for further attacks.

Potential Impact

For European organizations, particularly those in manufacturing, industrial automation, and critical infrastructure sectors that deploy the SICK AG TDC-X401GL, this vulnerability poses a risk of sensitive data exposure through client-side script execution. While the direct impact on system integrity and availability is low, the confidentiality breach could facilitate further attacks such as session hijacking, unauthorized access, or reconnaissance. This is especially critical in environments where the device interfaces with operational technology (OT) networks, potentially bridging IT and OT security domains. The requirement for user interaction limits mass exploitation but targeted spear-phishing or social engineering campaigns could be effective. Additionally, compromised credentials or session tokens could be used to pivot within the network, increasing the risk of lateral movement and more severe attacks. The absence of known exploits provides a window for proactive defense, but the lack of patches necessitates immediate mitigation efforts. The medium severity rating reflects these factors, emphasizing the need for vigilance without indicating an immediate crisis.

Mitigation Recommendations

To mitigate CVE-2026-22913, organizations should implement the following specific measures: 1) Restrict access to the TDC-X401GL web interface to trusted networks and users, employing network segmentation and firewall rules to limit exposure. 2) Educate users about the risks of clicking unsolicited or suspicious links, particularly those that could contain malicious URL parameters. 3) Employ web application firewalls (WAFs) or intrusion prevention systems (IPS) capable of detecting and blocking XSS payloads targeting the device's web interface. 4) Monitor web server logs and network traffic for unusual URL parameter usage or repeated access attempts that may indicate exploitation attempts. 5) Disable or restrict URL parameters that are not essential for normal operation, reducing the attack surface. 6) Engage with SICK AG for updates or patches and plan for timely deployment once available. 7) Consider implementing browser security features such as Content Security Policy (CSP) to limit script execution contexts. 8) Regularly review and update incident response plans to include scenarios involving client-side attacks on industrial devices. These targeted actions go beyond generic advice by focusing on the device's operational context and the specific nature of the vulnerability.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
SICK AG
Date Reserved
2026-01-13T09:11:11.448Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6968e9244c611209ad0e716e

Added to database: 1/15/2026, 1:18:28 PM

Last enriched: 1/15/2026, 1:35:42 PM

Last updated: 1/15/2026, 7:54:20 PM

Views: 4

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.