Skip to main content
CVE-2023-33919VulnerabilityPublished Updated

CVE-2023-33919: Siemens CP-8031 MASTER MODULE · Command Injection

Affects Siemens CP-8031 MASTER MODULESource CVE Database V5

0

Not known to be exploited · 47% EPSS · CVSS 7.2 High.

Data as of 25 Oct 2026, 19:02 UTC

CVSS 3.1 base score
7.2High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
47.7% chance of exploitation in 30 days – higher than 98% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 13 Jun 2023

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-25.

What to do

AI-suggested

1. Immediately upgrade affected Siemens CP-8031 and CP-8050 MASTER MODULE devices to firmware version CPCI85 V05 or later, where the vulnerability is patched. 2. Restrict access to the web management interface using network segmentation, firewall rules, and VPNs to limit exposure to trusted administrators only. 3. Enforce strong authentication mechanisms, including multi-factor authentication (MFA), to reduce the risk of credential compromise. 4. Regularly audit and monitor access logs for anomalous or unauthorized access attempts to the device interfaces. 5. Implement strict credential management policies, including regular password changes and least privilege principles for administrative accounts. 6. Conduct periodic vulnerability assessments and penetration testing focused on industrial control systems to detect similar issues proactively. 7. Maintain an incident response plan tailored to industrial control system compromises to quickly contain and remediate potential exploitation.

Description

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

References

Community reviews