Skip to main content

CVE-2023-46285: CWE-20: Improper Input Validation in Siemens Opcenter Execution Foundation

High
VulnerabilityCVE-2023-46285cvecve-2023-46285cwe-20
Published: Tue Dec 12 2023 (12/12/2023, 11:27:17 UTC)
Source: CVE
Vendor/Project: Siemens
Product: Opcenter Execution Foundation

Description

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.

AI-Powered Analysis

AILast updated: 07/08/2025, 20:28:09 UTC

Technical Analysis

CVE-2023-46285 is a high-severity vulnerability identified in multiple Siemens industrial software products, including Opcenter Execution Foundation (all versions prior to V2407), Opcenter Quality (all versions prior to V2312), SIMATIC PCS neo (all versions prior to V4.1), SINEC NMS (all versions prior to V2.0 SP1), and various versions of the Totally Integrated Automation Portal (TIA Portal) ranging from V14 up to V18 (with specific update thresholds). The root cause of this vulnerability is improper input validation (classified under CWE-20) in a service listening on TCP port 4004. An attacker can exploit this flaw by sending a specially crafted message to this port, which triggers a denial-of-service (DoS) condition by crashing the service. Although the affected service is automatically restarted by a watchdog mechanism, the repeated exploitation could lead to service instability or downtime. The vulnerability does not require authentication or user interaction and can be exploited remotely over the network, increasing its risk profile. The CVSS v3.1 base score is 7.5, reflecting high severity primarily due to the network attack vector, lack of required privileges, and the impact on availability. No known exploits are currently reported in the wild, and Siemens has not yet published patches for all affected versions, emphasizing the need for proactive mitigation. This vulnerability is particularly critical for industrial control systems and manufacturing execution environments where these Siemens products are deployed, as service disruptions can impact operational continuity and safety-critical processes.

Potential Impact

For European organizations, especially those operating in manufacturing, industrial automation, and critical infrastructure sectors, this vulnerability poses a significant risk. Siemens products affected by this vulnerability are widely used across Europe in factories, process control plants, and utilities. A successful DoS attack could disrupt production lines, delay quality assurance processes, and impair monitoring and control systems, leading to financial losses and potential safety hazards. Given the automatic service restart, the impact might be transient but could still cause repeated interruptions or degrade system reliability. Additionally, persistent DoS conditions could complicate incident response and maintenance activities. Organizations in Europe with high dependence on Siemens automation software may face operational downtime, regulatory scrutiny, and reputational damage if exploited. The lack of confidentiality or integrity impact reduces the risk of data breaches, but availability disruptions in industrial environments can have cascading effects on supply chains and critical services.

Mitigation Recommendations

European organizations should prioritize the following specific mitigation steps: 1) Immediate inventory and identification of Siemens products and versions in use, focusing on those listed as vulnerable. 2) Apply Siemens-provided patches or updates as soon as they become available, particularly updating to versions V2407 or later for Opcenter Execution Foundation and corresponding fixed versions for other products. 3) Implement network segmentation and restrict access to TCP port 4004 to trusted management networks only, using firewalls and access control lists to limit exposure. 4) Deploy intrusion detection/prevention systems (IDS/IPS) with signatures or anomaly detection tuned to identify malformed packets targeting port 4004. 5) Monitor service stability and logs for repeated crashes or restarts of the affected service to detect potential exploitation attempts early. 6) Coordinate with Siemens support for guidance and updates on patches or workarounds. 7) Incorporate this vulnerability into incident response plans, emphasizing rapid containment and recovery from DoS conditions. These targeted actions go beyond generic advice by focusing on network-level controls, proactive monitoring, and vendor coordination specific to the affected Siemens products and their operational context.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2023-10-20T10:29:46.260Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6831a1510acd01a24927bf47

Added to database: 5/24/2025, 10:37:05 AM

Last enriched: 7/8/2025, 8:28:09 PM

Last updated: 8/17/2025, 8:04:12 PM

Views: 13

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.