CVE-2023-49131: CWE-824: Access of Uninitialized Pointer in Siemens Solid Edge SE2023
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
AI Analysis
Technical Summary
CVE-2023-49131 is a high-severity vulnerability affecting Siemens Solid Edge SE2023 versions prior to V223.0 Update 10. The vulnerability is classified under CWE-824, which pertains to the access of uninitialized pointers. Specifically, the flaw arises during the parsing of specially crafted PAR files, where the application accesses memory pointers that have not been properly initialized. This can lead to undefined behavior, including the potential for an attacker to execute arbitrary code within the context of the current process. The vulnerability requires local access (AV:L) and user interaction (UI:R) to be exploited, but does not require any privileges (PR:N). The attack complexity is low (AC:L), meaning that an attacker with local access and the ability to trick a user into opening a malicious PAR file can reliably exploit the flaw. The impact on confidentiality, integrity, and availability is rated high, as successful exploitation could allow arbitrary code execution, potentially leading to full system compromise or data theft. No known exploits are currently reported in the wild, but the vulnerability is publicly disclosed and rated with a CVSS 3.1 score of 7.8, indicating a significant risk. Siemens has not yet published an official patch or update to remediate this issue, increasing the urgency for affected users to apply mitigations or upgrade once available. The vulnerability is particularly relevant for organizations using Solid Edge SE2023 for CAD and engineering design, as malicious PAR files could be delivered via email, shared drives, or other file transfer methods, exploiting user trust and interaction.
Potential Impact
For European organizations, the impact of CVE-2023-49131 is considerable, especially those in manufacturing, engineering, and industrial design sectors that rely heavily on Siemens Solid Edge SE2023 for product development. Exploitation could lead to unauthorized code execution, potentially allowing attackers to steal intellectual property, disrupt design workflows, or implant persistent malware within engineering environments. This could result in significant operational downtime, loss of competitive advantage, and exposure of sensitive design data. Given the local attack vector and requirement for user interaction, insider threats or targeted phishing campaigns are plausible attack scenarios. The high impact on confidentiality and integrity is critical for organizations handling proprietary designs or regulated data. Additionally, since Solid Edge is integrated into broader industrial and supply chain processes, compromise could cascade, affecting production lines or supply chain security. The absence of known exploits currently reduces immediate risk but does not eliminate the threat, especially as attackers often develop exploits rapidly after public disclosure.
Mitigation Recommendations
1. Immediate mitigation should focus on user awareness and restricting the handling of PAR files from untrusted sources. Implement strict email filtering and endpoint protections to detect and block malicious PAR files. 2. Enforce the principle of least privilege by limiting user permissions on workstations running Solid Edge SE2023 to reduce the impact of potential code execution. 3. Employ application whitelisting and behavior-based endpoint detection and response (EDR) solutions to identify and block suspicious activities related to Solid Edge processes. 4. Isolate engineering workstations in segmented network zones to limit lateral movement if exploitation occurs. 5. Siemens users should monitor official Siemens channels for the release of patches or updates and prioritize timely application once available. 6. Conduct regular backups of critical design data and verify recovery processes to minimize disruption from potential attacks. 7. Consider deploying sandboxing or virtual desktop infrastructure (VDI) for opening untrusted PAR files to contain potential exploitation. 8. Review and update incident response plans to include scenarios involving CAD software compromise.
Affected Countries
Germany, France, Italy, United Kingdom, Spain, Netherlands, Belgium, Sweden, Finland, Poland
CVE-2023-49131: CWE-824: Access of Uninitialized Pointer in Siemens Solid Edge SE2023
Description
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
AI-Powered Analysis
Technical Analysis
CVE-2023-49131 is a high-severity vulnerability affecting Siemens Solid Edge SE2023 versions prior to V223.0 Update 10. The vulnerability is classified under CWE-824, which pertains to the access of uninitialized pointers. Specifically, the flaw arises during the parsing of specially crafted PAR files, where the application accesses memory pointers that have not been properly initialized. This can lead to undefined behavior, including the potential for an attacker to execute arbitrary code within the context of the current process. The vulnerability requires local access (AV:L) and user interaction (UI:R) to be exploited, but does not require any privileges (PR:N). The attack complexity is low (AC:L), meaning that an attacker with local access and the ability to trick a user into opening a malicious PAR file can reliably exploit the flaw. The impact on confidentiality, integrity, and availability is rated high, as successful exploitation could allow arbitrary code execution, potentially leading to full system compromise or data theft. No known exploits are currently reported in the wild, but the vulnerability is publicly disclosed and rated with a CVSS 3.1 score of 7.8, indicating a significant risk. Siemens has not yet published an official patch or update to remediate this issue, increasing the urgency for affected users to apply mitigations or upgrade once available. The vulnerability is particularly relevant for organizations using Solid Edge SE2023 for CAD and engineering design, as malicious PAR files could be delivered via email, shared drives, or other file transfer methods, exploiting user trust and interaction.
Potential Impact
For European organizations, the impact of CVE-2023-49131 is considerable, especially those in manufacturing, engineering, and industrial design sectors that rely heavily on Siemens Solid Edge SE2023 for product development. Exploitation could lead to unauthorized code execution, potentially allowing attackers to steal intellectual property, disrupt design workflows, or implant persistent malware within engineering environments. This could result in significant operational downtime, loss of competitive advantage, and exposure of sensitive design data. Given the local attack vector and requirement for user interaction, insider threats or targeted phishing campaigns are plausible attack scenarios. The high impact on confidentiality and integrity is critical for organizations handling proprietary designs or regulated data. Additionally, since Solid Edge is integrated into broader industrial and supply chain processes, compromise could cascade, affecting production lines or supply chain security. The absence of known exploits currently reduces immediate risk but does not eliminate the threat, especially as attackers often develop exploits rapidly after public disclosure.
Mitigation Recommendations
1. Immediate mitigation should focus on user awareness and restricting the handling of PAR files from untrusted sources. Implement strict email filtering and endpoint protections to detect and block malicious PAR files. 2. Enforce the principle of least privilege by limiting user permissions on workstations running Solid Edge SE2023 to reduce the impact of potential code execution. 3. Employ application whitelisting and behavior-based endpoint detection and response (EDR) solutions to identify and block suspicious activities related to Solid Edge processes. 4. Isolate engineering workstations in segmented network zones to limit lateral movement if exploitation occurs. 5. Siemens users should monitor official Siemens channels for the release of patches or updates and prioritize timely application once available. 6. Conduct regular backups of critical design data and verify recovery processes to minimize disruption from potential attacks. 7. Consider deploying sandboxing or virtual desktop infrastructure (VDI) for opening untrusted PAR files to contain potential exploitation. 8. Review and update incident response plans to include scenarios involving CAD software compromise.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- siemens
- Date Reserved
- 2023-11-22T14:53:05.160Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d983ac4522896dcbed146
Added to database: 5/21/2025, 9:09:14 AM
Last enriched: 6/25/2025, 4:39:36 PM
Last updated: 7/29/2025, 8:51:00 AM
Views: 11
Related Threats
CVE-2025-8976: Cross Site Scripting in givanz Vvveb
MediumCVE-2025-8980: Insufficient Verification of Data Authenticity in Tenda G1
HighCVE-2025-8979: Insufficient Verification of Data Authenticity in Tenda AC15
HighCVE-2025-8975: Cross Site Scripting in givanz Vvveb
MediumCVE-2025-55716: CWE-862 Missing Authorization in VeronaLabs WP Statistics
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.