Skip to main content

CVE-2023-52508: Vulnerability in Linux Linux

Medium
VulnerabilityCVE-2023-52508cvecve-2023-52508
Published: Sat Mar 02 2024 (03/02/2024, 21:52:21 UTC)
Source: CVE
Vendor/Project: Linux
Product: Linux

Description

In the Linux kernel, the following vulnerability has been resolved: nvme-fc: Prevent null pointer dereference in nvme_fc_io_getuuid() The nvme_fc_fcp_op structure describing an AEN operation is initialized with a null request structure pointer. An FC LLDD may make a call to nvme_fc_io_getuuid passing a pointer to an nvmefc_fcp_req for an AEN operation. Add validation of the request structure pointer before dereference.

AI-Powered Analysis

AILast updated: 07/01/2025, 09:57:19 UTC

Technical Analysis

CVE-2023-52508 is a medium-severity vulnerability identified in the Linux kernel, specifically within the NVMe over Fibre Channel (nvme-fc) driver subsystem. The vulnerability arises due to a null pointer dereference in the function nvme_fc_io_getuuid(). This function is called with a pointer to an nvmefc_fcp_req structure representing an Asynchronous Event Notification (AEN) operation. However, the nvme_fc_fcp_op structure describing this AEN operation is initialized with a null request structure pointer. If the Fibre Channel lower-level driver (FC LLDD) invokes nvme_fc_io_getuuid() with this null pointer, the function attempts to dereference it without validation, leading to a null pointer dereference. This can cause the affected system to crash or become unstable, resulting in a denial of service (DoS) condition. The vulnerability is classified under CWE-476 (NULL Pointer Dereference). The CVSS v3.1 base score is 5.5 (medium severity), with the vector indicating local attack vector (AV:L), low attack complexity (AC:L), requiring low privileges (PR:L), no user interaction (UI:N), unchanged scope (S:U), no confidentiality or integrity impact (C:N/I:N), but high impact on availability (A:H). The vulnerability does not appear to have known exploits in the wild as of the publication date (March 2, 2024). The fix involves adding validation checks for the request structure pointer before dereferencing it to prevent the null pointer dereference. This vulnerability affects Linux kernel versions identified by the commit hash 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, indicating a specific patch or kernel version lineage. Since the nvme-fc driver is used in environments where NVMe storage is accessed over Fibre Channel networks, this vulnerability is relevant primarily to enterprise and data center Linux deployments that utilize NVMe over FC storage architectures.

Potential Impact

For European organizations, the primary impact of CVE-2023-52508 is the potential for denial of service on Linux systems that use NVMe over Fibre Channel storage. This could disrupt critical storage access in data centers, affecting availability of applications and services relying on these storage backends. Industries such as finance, telecommunications, cloud service providers, and large enterprises with high-performance storage needs are more likely to be affected. The vulnerability does not compromise confidentiality or integrity, but availability impacts can lead to operational downtime, service interruptions, and potential financial losses. Given the local attack vector and requirement for low privileges, exploitation would typically require an attacker or malicious insider with some level of access to the affected system. This limits the risk from remote attackers but raises concerns about insider threats or compromised local accounts. The lack of user interaction requirement means that once local access is obtained, exploitation can be automated or triggered without further user involvement. The absence of known exploits in the wild reduces immediate risk but does not eliminate the need for timely patching, especially in sensitive or high-availability environments.

Mitigation Recommendations

European organizations should prioritize updating their Linux kernels to versions that include the patch for CVE-2023-52508. Since the vulnerability is in the nvme-fc driver, organizations should: 1) Identify all Linux systems using NVMe over Fibre Channel storage by auditing storage configurations and kernel modules. 2) Apply vendor-provided kernel updates or patches that address this specific vulnerability. 3) If immediate patching is not feasible, consider temporarily disabling the nvme-fc driver or restricting access to systems with NVMe over FC to trusted administrators only. 4) Implement strict access controls and monitoring on systems with local user accounts to detect unauthorized or suspicious activities that could lead to exploitation attempts. 5) Use kernel hardening techniques such as SELinux or AppArmor profiles to limit the impact of potential exploitation. 6) Regularly review and update incident response plans to include scenarios involving denial of service caused by kernel-level vulnerabilities. 7) Engage with hardware and storage vendors to ensure compatibility and support for updated kernel versions. These steps go beyond generic advice by focusing on the specific subsystem affected and the operational context of NVMe over Fibre Channel deployments.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
Linux
Date Reserved
2024-02-20T12:30:33.315Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d9831c4522896dcbe7bc0

Added to database: 5/21/2025, 9:09:05 AM

Last enriched: 7/1/2025, 9:57:19 AM

Last updated: 8/4/2025, 12:41:44 AM

Views: 11

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.