CVE-2024-32008: CWE-648: Incorrect Use of Privileged APIs in Siemens Spectrum Power 4
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to an exposed debug interface on the localhost. This allows any local user to gain code execution as administrative application user.
AI Analysis
Technical Summary
CVE-2024-32008 is a vulnerability classified under CWE-648 (Incorrect Use of Privileged APIs) affecting Siemens Spectrum Power 4 software versions earlier than V4.70 SP12 Update 2. The root cause is an exposed debug interface that listens on the localhost interface, which is intended for debugging purposes but is improperly secured. This interface can be accessed by any local user, enabling them to execute arbitrary code with the administrative privileges of the application. Because the vulnerability requires local access (AV:L) and low attack complexity (AC:L), it is relatively easy to exploit by an authenticated local user without requiring any user interaction (UI:N). The impact is severe, affecting confidentiality, integrity, and availability (all rated high), as an attacker can gain full control over the application and potentially escalate further within the system. Siemens Spectrum Power 4 is a critical energy management system used by utilities to monitor and control electrical grids, making this vulnerability particularly sensitive. Although no exploits are currently known in the wild, the presence of an exposed debug interface is a significant security oversight that could be leveraged by malicious insiders or attackers who have gained local access. The vulnerability was publicly disclosed on November 11, 2025, with a CVSS v3.1 score of 7.8, indicating high severity. Siemens has not yet published a patch or mitigation guidance, so affected organizations must implement interim controls to limit local access and monitor for suspicious activity.
Potential Impact
For European organizations, especially those in the energy sector using Siemens Spectrum Power 4, this vulnerability poses a substantial risk. Exploitation could lead to unauthorized administrative control over critical grid management software, potentially disrupting power distribution, causing outages, or enabling sabotage. Confidentiality breaches could expose sensitive operational data, while integrity compromises could allow manipulation of grid control commands. Availability impacts could result in denial of service or system instability. Given the strategic importance of energy infrastructure in Europe and the reliance on Siemens products, this vulnerability could have cascading effects on national grid stability and security. Insider threats or attackers who gain local access through other means (e.g., compromised credentials, lateral movement) could exploit this flaw to escalate privileges and cause significant operational damage.
Mitigation Recommendations
1. Restrict local access to systems running Siemens Spectrum Power 4 to trusted personnel only, employing strict access controls and monitoring. 2. Disable or restrict the debug interface if configuration options allow, preventing exposure even on localhost. 3. Implement host-based intrusion detection systems (HIDS) to monitor for unusual local access or code execution attempts. 4. Enforce strong endpoint security measures to prevent unauthorized local user creation or lateral movement. 5. Regularly audit local user accounts and permissions on affected systems. 6. Segregate network zones to limit access to critical management systems. 7. Apply the official Siemens patch or update to version V4.70 SP12 Update 2 as soon as it becomes available. 8. Conduct security awareness training for administrators and operators about the risks of local privilege escalation and the importance of securing local access.
Affected Countries
Germany, France, United Kingdom, Italy, Spain, Netherlands, Belgium, Poland, Sweden, Finland
CVE-2024-32008: CWE-648: Incorrect Use of Privileged APIs in Siemens Spectrum Power 4
Description
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to an exposed debug interface on the localhost. This allows any local user to gain code execution as administrative application user.
AI-Powered Analysis
Technical Analysis
CVE-2024-32008 is a vulnerability classified under CWE-648 (Incorrect Use of Privileged APIs) affecting Siemens Spectrum Power 4 software versions earlier than V4.70 SP12 Update 2. The root cause is an exposed debug interface that listens on the localhost interface, which is intended for debugging purposes but is improperly secured. This interface can be accessed by any local user, enabling them to execute arbitrary code with the administrative privileges of the application. Because the vulnerability requires local access (AV:L) and low attack complexity (AC:L), it is relatively easy to exploit by an authenticated local user without requiring any user interaction (UI:N). The impact is severe, affecting confidentiality, integrity, and availability (all rated high), as an attacker can gain full control over the application and potentially escalate further within the system. Siemens Spectrum Power 4 is a critical energy management system used by utilities to monitor and control electrical grids, making this vulnerability particularly sensitive. Although no exploits are currently known in the wild, the presence of an exposed debug interface is a significant security oversight that could be leveraged by malicious insiders or attackers who have gained local access. The vulnerability was publicly disclosed on November 11, 2025, with a CVSS v3.1 score of 7.8, indicating high severity. Siemens has not yet published a patch or mitigation guidance, so affected organizations must implement interim controls to limit local access and monitor for suspicious activity.
Potential Impact
For European organizations, especially those in the energy sector using Siemens Spectrum Power 4, this vulnerability poses a substantial risk. Exploitation could lead to unauthorized administrative control over critical grid management software, potentially disrupting power distribution, causing outages, or enabling sabotage. Confidentiality breaches could expose sensitive operational data, while integrity compromises could allow manipulation of grid control commands. Availability impacts could result in denial of service or system instability. Given the strategic importance of energy infrastructure in Europe and the reliance on Siemens products, this vulnerability could have cascading effects on national grid stability and security. Insider threats or attackers who gain local access through other means (e.g., compromised credentials, lateral movement) could exploit this flaw to escalate privileges and cause significant operational damage.
Mitigation Recommendations
1. Restrict local access to systems running Siemens Spectrum Power 4 to trusted personnel only, employing strict access controls and monitoring. 2. Disable or restrict the debug interface if configuration options allow, preventing exposure even on localhost. 3. Implement host-based intrusion detection systems (HIDS) to monitor for unusual local access or code execution attempts. 4. Enforce strong endpoint security measures to prevent unauthorized local user creation or lateral movement. 5. Regularly audit local user accounts and permissions on affected systems. 6. Segregate network zones to limit access to critical management systems. 7. Apply the official Siemens patch or update to version V4.70 SP12 Update 2 as soon as it becomes available. 8. Conduct security awareness training for administrators and operators about the risks of local privilege escalation and the importance of securing local access.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- siemens
- Date Reserved
- 2024-04-08T15:37:27.222Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 6913a08bf4d5bbdab5b1c728
Added to database: 11/11/2025, 8:46:03 PM
Last enriched: 11/18/2025, 10:34:36 PM
Last updated: 11/22/2025, 3:18:07 PM
Views: 36
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2023-30806: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Sangfor Net-Gen Application Firewall
CriticalCVE-2024-0401: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in ASUS ExpertWiFi
HighCVE-2024-23690: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Netgear FVS336Gv3
HighCVE-2024-13976: CWE-427 Uncontrolled Search Path Element in Commvault Commvault for Windows
HighCVE-2024-12856: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Four-Faith F3x24
HighActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.