Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.

AI-Powered Analysis

AILast updated: 06/25/2025, 15:33:29 UTC

Technical Analysis

CVE-2024-39871 is a medium-severity vulnerability affecting Siemens SINEMA Remote Connect Server versions prior to V3.2 SP1. The issue stems from incorrect authorization controls within the application, specifically a failure to properly separate permissions related to editing device settings and managing communication relation settings. This flaw allows an authenticated user who has permission to manage devices to escalate their privileges by gaining unauthorized access to participant groups that they are not a member of. Essentially, the vulnerability is an instance of CWE-863 (Incorrect Authorization), where the access control mechanisms do not enforce proper boundaries between different administrative functions. Exploitation requires the attacker to be authenticated with device management rights, but no user interaction beyond that is necessary. The vulnerability impacts confidentiality, integrity, and availability to a limited extent, as unauthorized access to participant groups could lead to unauthorized configuration changes or information disclosure within the SINEMA Remote Connect Server environment. The CVSS 3.1 base score is 6.3, reflecting network attack vector, low attack complexity, and privileges required, with partial impacts on confidentiality, integrity, and availability. No known exploits are currently reported in the wild, and Siemens has not yet published patches as of the data provided. This vulnerability is particularly relevant for industrial and critical infrastructure environments where SINEMA Remote Connect Server is deployed to manage remote connections securely.

Potential Impact

For European organizations, especially those in industrial sectors such as manufacturing, energy, utilities, and critical infrastructure, this vulnerability poses a risk of unauthorized access within remote connection management systems. SINEMA Remote Connect Server is widely used in Europe for secure remote access to industrial control systems (ICS) and operational technology (OT) networks. Exploitation could allow an attacker with limited privileges to escalate access, potentially leading to unauthorized configuration changes, disruption of communication relations, or exposure of sensitive network topology information. This could degrade operational integrity and availability, increasing the risk of operational disruptions or facilitating further attacks on ICS environments. Given the strategic importance of industrial automation in Europe’s economy and critical infrastructure, exploitation could have cascading effects on production continuity and safety. The vulnerability’s requirement for authenticated access limits exposure to insider threats or attackers who have already compromised credentials, but the risk remains significant in environments with multiple administrators or shared credentials. The lack of a patch at present increases the urgency for mitigation.

Mitigation Recommendations

1. Immediate review and restriction of user permissions within SINEMA Remote Connect Server to ensure the principle of least privilege is strictly enforced, limiting device management rights only to trusted personnel. 2. Implement strong authentication mechanisms, such as multi-factor authentication (MFA), for all users with device management permissions to reduce the risk of credential compromise. 3. Monitor and audit user activities related to device and communication relation settings to detect any unauthorized access or privilege escalation attempts. 4. Segment the network to isolate SINEMA Remote Connect Server from less trusted networks and limit access to it via secure VPNs or jump hosts. 5. Until Siemens releases a patch, consider deploying compensating controls such as enhanced logging, alerting on configuration changes, and temporary disabling of non-essential user accounts with device management rights. 6. Engage with Siemens support channels to obtain early access to patches or workarounds as they become available. 7. Conduct security awareness training for administrators to recognize and report suspicious activities related to remote connection management. These steps go beyond generic advice by focusing on permission management, monitoring, and network segmentation tailored to the specific nature of this vulnerability.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2024-07-01T13:05:40.288Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d983ac4522896dcbed259

Added to database: 5/21/2025, 9:09:14 AM

Last enriched: 6/25/2025, 3:33:29 PM

Last updated: 7/27/2025, 11:32:45 AM

Views: 13

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats