CVE-2024-56073: fastnetmon · n/a
Affects fastnetmonSource CVE Database V5
Not known to be exploited · CVSS 7.5 High : upgrade to 1.2.8 soon.
Data as of 26 Oct 2026, 06:26 UTC
- EPSS
- 0.5% chance of exploitation in 30 days – higher than 48% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in 1.2.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HExploitation evidence
Disclosed: evidence found.
CVE published 15 Dec 2024
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.
What to do
Upgrade pavel-odintsov/fastnetmon to 1.2.8.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
GitHubpavel-odintsov/fastnetmonpkg:github/pavel-odintsov/fastnetmonOther threats | Affected
| Fixed in
|
Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.
AI-suggested
1. Upgrade FastNetMon to a version that addresses this vulnerability once an official patch is released. 2. Implement network-level filtering to block or restrict Netflow v9 traffic from untrusted or external sources, reducing exposure to crafted packets. 3. Deploy intrusion detection or prevention systems (IDS/IPS) with signatures or anomaly detection rules to identify and block malformed Netflow v9 templates. 4. Isolate FastNetMon instances within secure network segments to limit access to trusted monitoring infrastructure only. 5. Regularly audit and monitor FastNetMon logs and system health to detect abnormal crashes or service interruptions promptly. 6. Consider fallback or redundancy mechanisms for network monitoring to maintain visibility during FastNetMon outages. 7. Engage with the FastNetMon community or support channels to obtain early access to patches or workarounds. 8. If immediate patching is not possible, temporarily disable Netflow v9 processing or limit the acceptance of Netflow data to trusted sources only, if configurable.
Description
An issue was discovered in FastNetMon Community Edition through 1.2.7. Zero-length templates for Netflow v9 allow remote attackers to cause a denial of service (divide-by-zero error and application crash).