Skip to main content
CVE-2025-2182VulnerabilityPublished

CVE-2025-2182: Palo Alto Networks Cloud NGFW · Cleartext Storage of Sensitive Information

Affects Palo Alto Networks Cloud NGFWSource CVE Database V5

0

Not known to be exploited · CVSS 5.6 Medium.

Data as of 25 Oct 2026, 19:02 UTC

CVSS 4.0 base score
5.6Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.1% chance of exploitation in 30 days – higher than 1% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:P/AC:L/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N/AU:N/R:A/V:D/RE:M/U:Amber

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 13 Aug 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-25.

What to do

AI-suggested

1. Immediate mitigation should focus on restricting access to the PA-7500 devices and their stored keys, ensuring only trusted administrators have high-level privileges. 2. Disable MACsec on NGFW clusters if it is not strictly required, to eliminate exposure of the CAK. 3. Monitor and audit access logs for any unusual administrative activity or attempts to access key storage areas on the devices. 4. Implement network segmentation and strict access controls around firewall management interfaces to reduce the risk of key compromise. 5. Upon availability, promptly apply vendor patches or firmware updates addressing this vulnerability. 6. Consider deploying additional encryption or key management solutions external to the firewall cluster to protect sensitive keys. 7. Conduct regular security assessments and penetration tests focusing on key management and inter-device communication security within NGFW clusters. 8. Educate network and security teams about the risks of cleartext key storage and best practices for secure key handling in clustered environments.

Description

A problem with the implementation of the MACsec protocol in Palo Alto Networks PAN-OS® results in the cleartext exposure of the connectivity association key (CAK). This issue is only applicable to PA-7500 Series devices which are in an NGFW cluster. A user who possesses this key can read messages being sent between devices in a NGFW Cluster. There is no impact in non-clustered firewalls or clusters of firewalls that do not enable MACsec.

References

Community reviews