CVE-2025-9060: MSoft MFlash · Improper Input Validation
Affects MSoft MFlashSource CVE Database V5
Not known to be exploited · CVSS 9.1 Critical.
Data as of 22 Nov 2026, 21:14 UTC
- EPSS
- 0.6% chance of exploitation in 30 days – higher than 51% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:HExploitation evidence
Disclosed: evidence found.
CVE published 15 Aug 2025
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 22 Nov 2026.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| MSoft MFlash | Affected
| Fixed in– |
AI-suggested
European organizations should prioritize applying the vendor-provided hotfix (version 8.2-653 hotfix 11.06.2025 or later) immediately to remediate this vulnerability. Beyond patching, organizations should implement strict access controls and monitoring around MFlash administrator accounts to prevent unauthorized access. Employ multi-factor authentication (MFA) for all administrative access to reduce the risk of credential compromise. Network segmentation should be enforced to limit exposure of MFlash servers to untrusted networks. Regular auditing and logging of administrative actions within MFlash can help detect suspicious activities early. Additionally, organizations should conduct thorough input validation reviews and consider deploying web application firewalls (WAFs) with rules tailored to detect anomalous parameter inputs related to MFlash integration configurations. Incident response plans should be updated to include scenarios involving MFlash compromise, ensuring rapid containment and recovery.
Description
A vulnerability has been found in the MSoft MFlash application that allows execution of arbitrary code on the server. The issue occurs in the integration configuration functionality that is only available to MFlash administrators. The vulnerability is related to insufficient validation of parameters when setting up security components. This issue affects MFlash v.8.0 and possibly others. To mitigate apply 8.2-653 hotfix 11.06.2025 and above.