Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2026-25084: CWE-306 Missing Authentication for Critical Function in ZLAN Information Technology Co. ZLAN5143D

0
Critical
VulnerabilityCVE-2026-25084cvecve-2026-25084cwe-306
Published: Wed Feb 11 2026 (02/11/2026, 16:11:08 UTC)
Source: CVE Database V5
Vendor/Project: ZLAN Information Technology Co.
Product: ZLAN5143D

Description

Authentication for ZLAN5143D can be bypassed by directly accessing internal URLs.

AI-Powered Analysis

AILast updated: 02/11/2026, 17:00:42 UTC

Technical Analysis

CVE-2026-25084 identifies a critical security vulnerability in the ZLAN5143D device produced by ZLAN Information Technology Co., specifically in version 1.600. The vulnerability is classified under CWE-306, which pertains to missing authentication for critical functions. In this case, the device's authentication mechanism can be bypassed by directly accessing internal URLs, effectively allowing unauthenticated attackers to reach sensitive functions without credentials. The CVSS v3.1 base score is 9.8, reflecting the vulnerability's high severity with metrics indicating network attack vector (AV:N), low attack complexity (AC:L), no privileges required (PR:N), no user interaction (UI:N), unchanged scope (S:U), and high impact on confidentiality (C:H), integrity (I:H), and availability (A:H). This means an attacker can remotely exploit the vulnerability without any prior access or user involvement, potentially leading to full compromise of the device. The lack of authentication on critical functions exposes the device to unauthorized configuration changes, data leakage, or denial of service. Although no public exploits have been observed yet, the vulnerability's nature and severity make it a prime target for attackers once exploit code becomes available. The absence of patch links suggests that a fix may not yet be released, increasing the urgency for interim protective measures. The vulnerability was published on February 11, 2026, and assigned by ICS-CERT, indicating its relevance to industrial control systems or critical infrastructure environments where such devices might be deployed.

Potential Impact

For European organizations, the impact of CVE-2026-25084 is substantial. The ZLAN5143D device, likely used in network infrastructure or industrial control systems, if compromised, can lead to unauthorized access to sensitive network segments or critical operational technology environments. This can result in data breaches, manipulation of device configurations, disruption of services, or complete denial of availability. Given the high CVSS score and the nature of the vulnerability, attackers could leverage this flaw to pivot within networks, escalate privileges, or disrupt critical services. Organizations in sectors such as energy, manufacturing, telecommunications, and government are particularly at risk, as these sectors often rely on specialized network devices for operational continuity. The absence of authentication on critical functions undermines trust in device security and can lead to regulatory non-compliance under frameworks like GDPR if personal data is exposed. Additionally, the potential for widespread impact exists if these devices are deployed at scale across European networks without adequate protections.

Mitigation Recommendations

To mitigate CVE-2026-25084, European organizations should implement the following specific measures: 1) Immediately isolate ZLAN5143D devices from public or untrusted networks by placing them behind firewalls or within segmented network zones that restrict access to management interfaces. 2) Employ strict access control lists (ACLs) to limit which IP addresses can reach the device’s internal URLs, ideally restricting access to trusted administrative workstations only. 3) Monitor network traffic for unusual or unauthorized access attempts to internal URLs associated with the device, using intrusion detection/prevention systems (IDS/IPS) and security information and event management (SIEM) tools. 4) Engage with ZLAN Information Technology Co. to obtain any available patches or firmware updates addressing this vulnerability; if none are available, request timelines and interim guidance. 5) Consider deploying compensating controls such as VPNs with multi-factor authentication (MFA) for remote access to device management interfaces. 6) Conduct thorough audits of device configurations and logs to detect any signs of exploitation or unauthorized changes. 7) Develop and test incident response plans specific to network device compromise scenarios. These steps go beyond generic advice by focusing on network architecture adjustments, proactive monitoring, and vendor engagement tailored to this vulnerability’s characteristics.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
icscert
Date Reserved
2026-01-29T21:07:29.846Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 698cb25d4b57a58fa1a7484e

Added to database: 2/11/2026, 4:46:21 PM

Last enriched: 2/11/2026, 5:00:42 PM

Last updated: 2/11/2026, 5:50:48 PM

Views: 4

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats