Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page.
If a benign user with appropriate rights accesses the "Motion Control Diagnostics" parameters page, the malicious code would be executed in the scope of their web session.
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface.
This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page.
If a benign user with appropriate rights accesses the "communication" parameters page, the malicious code would be executed in the scope of their web session.
CVE-2026-22925 is a high-severity vulnerability in Siemens SIMATIC CN 4100 versions prior to V5.0. It involves allocation of resources without limits or throttling, making the system susceptible to resource exhaustion when subjected to a high volume of TCP SYN packets. This can lead to denial-of-service (DoS) conditions by overwhelming system resources and rendering the service unavailable. No official patch or remediation guidance has been provided yet. There are no known exploits in the wild at this time.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V5.0). The affected application does not properly restrict unauthenticated connections and is susceptible to resource exhaustion conditions.
This could allow an attacker to disrupt normal operations or perform unauthorized actions, potentially impacting system availability and integrity.
CVE-2025-40948 is a vulnerability in multiple versions of Siemens RUGGEDCOM ROX MX5000 series devices prior to version 2.17.1. The issue arises from improper validation of input in the web server's JSON-RPC interface, classified as CWE-88 (Improper Neutralization of Argument Delimiters in a Command). An authenticated remote attacker could exploit this flaw to read arbitrary files on the underlying operating system with root privileges. The vulnerability has a CVSS 3.1 base score of 6.8, indicating medium severity. No official patch or remediation guidance has been provided yet by Siemens. There are no known exploits in the wild at this time.
CVE-2025-40947 is a high-severity OS command injection vulnerability affecting multiple Siemens RUGGEDCOM ROX MX5000 series devices running versions prior to V2.17.1. The issue arises from improper sanitization of user input during the feature key installation process, allowing an authenticated remote attacker to execute arbitrary commands with root privileges on the underlying operating system. This vulnerability has a CVSS score of 7.5, indicating a significant risk. No official patch or remediation guidance is currently provided by the vendor. There are no known exploits in the wild at this time.
The affected devices contain a null pointer dereference vulnerability while processing specially crafted IPv4 requests. This could allow an attacker to cause denial of service condition. A manual restart is required to recover the system.
A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.
This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.
Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.
Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g.app specific authentication) are not affected.
A vulnerability has been identified in RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) (All versions < V5.8). User Administrators are allowed to administer groups they belong to. This could allow an authenticated User Administrator to escalate their own privileges and grant themselves access to any device group at any access level.
CVE-2026-25654 is a high-severity vulnerability in Siemens SINEC NMS versions prior to V4.0 SP3. The issue arises from improper validation of user authorization during password reset requests. An authenticated remote attacker with limited privileges could exploit this flaw to bypass authorization checks and reset the password of any arbitrary user account. This vulnerability impacts confidentiality, integrity, and availability of the affected system. No official patch or remediation guidance has been provided yet by Siemens. There are no known exploits in the wild at this time.
CVE-2026-24032 is a vulnerability in Siemens SINEC NMS versions prior to V4.0 SP3 with UMC. It involves improper verification of cryptographic signatures in the UMC component, leading to an authentication weakness. This flaw could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. The vulnerability has a CVSS 3.1 base score of 7.3, indicating high severity. No official patch or remediation guidance has been provided by Siemens as of the published date. There are no known exploits in the wild at this time.
A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (All versions < V2602), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Tecnomatix Plant Simulation (All versions < V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), SICORE Base system (All versions < V26.10.0). The affected application contains an out-of-bounds write vulnerability while parsing specially crafted XML inputs. This could allow an unauthenticated attacker to exploit this issue by sending a malicious XML request, which may cause the service to crash, resulting in a denial-of-service condition.
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), RTUM85 RTU Base (All versions < V26.10). The affected application contains denial-of-service (DoS) vulnerability. The remote operation mode is susceptible to a resource exhaustion condition when subjected to a high volume of requests. Sending multiple requests can exhaust resources, preventing parameterization and requiring a reset or reboot to restore functionality.
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application leaks confidential information in metadata, and files such as information on contributors and email address, on `SSM Server`.
A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). The affected application performs file deletion without properly validating the file path or target. An attacker could delete files or sockets that the affected process has permission to remove, potentially resulting in denial of service or service disruption.
A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). The affected application builds shell commands with caller-provided strings and executes them. An attacker could influence the executed command, potentially resulting in command injection and full system compromise.