Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2024-38447: n/a

0
High
VulnerabilityCVE-2024-38447cvecve-2024-38447
Published: Wed Jul 17 2024 (07/17/2024, 00:00:00 UTC)
Source: CVE Database V5

Description

CVE-2024-38447 is a high-severity vulnerability in NATO NCI ANET 3. 4. 1 that allows an attacker with limited privileges to access private draft reports belonging to arbitrary users by manipulating an ID field in requests. This Insecure Direct Object Reference (IDOR) flaw compromises confidentiality and integrity without requiring user interaction. Exploitation can lead to unauthorized disclosure and modification of sensitive information. Although no public exploits are currently known, the vulnerability poses a significant risk to organizations using this software, especially those handling classified or sensitive data. Mitigation requires strict access control validation on object references and prompt patching once available. Countries with NATO presence or reliance on NATO communication infrastructure are most at risk. The vulnerability has a CVSS score of 8. 1, reflecting its high impact and ease of exploitation with low privileges and no user interaction required.

AI-Powered Analysis

AILast updated: 02/26/2026, 05:35:05 UTC

Technical Analysis

CVE-2024-38447 identifies a critical security vulnerability classified as an Insecure Direct Object Reference (IDOR) in NATO NCI ANET version 3.4.1. The flaw arises because the application does not properly validate the ID field in requests for private draft reports, allowing an authenticated user with limited privileges (PR:L) to modify the ID parameter and access draft reports belonging to other users. This bypasses intended access controls, leading to unauthorized disclosure (confidentiality impact) and unauthorized modification (integrity impact) of sensitive documents. The vulnerability does not require user interaction (UI:N) and can be exploited remotely over the network (AV:N) with low attack complexity (AC:L). The scope is unchanged (S:U), meaning the impact is confined to the vulnerable component but affects multiple users’ data. The CVSS 3.1 base score is 8.1, indicating a high severity level. The weakness is categorized under CWE-639, which relates to authorization bypass through improper validation of object references. No patches or public exploits have been reported yet, but the nature of the vulnerability suggests that attackers with legitimate access could leverage this flaw to escalate their access and compromise sensitive information within NATO’s network infrastructure.

Potential Impact

The vulnerability poses a significant risk to organizations using NATO NCI ANET 3.4.1, particularly those handling sensitive or classified information. Unauthorized access to private draft reports can lead to leakage of confidential operational data, strategic plans, or intelligence, potentially undermining national security and operational effectiveness. Integrity impacts allow attackers to alter reports, which could disrupt decision-making processes or propagate misinformation. Since the flaw requires only limited privileges and no user interaction, it lowers the barrier for insider threats or compromised accounts to escalate their access. The absence of known exploits in the wild currently limits immediate risk, but the high CVSS score and critical nature of the affected systems mean that exploitation could have severe consequences. Organizations may face reputational damage, operational disruption, and increased risk of espionage or sabotage if this vulnerability is exploited.

Mitigation Recommendations

Organizations should immediately review and strengthen access control mechanisms for object references within NATO NCI ANET, ensuring that all requests for draft reports validate user permissions against the requested resource. Implement strict server-side authorization checks that do not rely solely on client-supplied identifiers. Conduct thorough code audits focusing on ID handling and access control logic. Monitor logs for unusual access patterns or repeated attempts to access unauthorized draft reports. Until an official patch is released, consider restricting access to the affected application to trusted networks and users with a demonstrated need. Employ multi-factor authentication and least privilege principles to reduce the risk of compromised credentials being used to exploit this vulnerability. Engage with NATO cybersecurity teams for guidance and updates on patch availability and deployment. Additionally, conduct user training to raise awareness about the risks of privilege misuse and insider threats.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.1
Assigner Short Name
mitre
Date Reserved
2024-06-16T00:00:00.000Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 699f6c7ab7ef31ef0b564ce8

Added to database: 2/25/2026, 9:41:14 PM

Last enriched: 2/26/2026, 5:35:05 AM

Last updated: 2/26/2026, 11:09:10 AM

Views: 1

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats