Skip to main content

CVE-2025-40582: CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Siemens SCALANCE LPE9403

High
VulnerabilityCVE-2025-40582cvecve-2025-40582cwe-78
Published: Tue May 13 2025 (05/13/2025, 09:39:10 UTC)
Source: CVE
Vendor/Project: Siemens
Product: SCALANCE LPE9403

Description

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions with SINEMA Remote Connect Edge Client installed). Affected devices do not properly sanitize configuration parameters. This could allow a non-privileged local attacker to execute root commands on the device.

AI-Powered Analysis

AILast updated: 07/12/2025, 02:16:28 UTC

Technical Analysis

CVE-2025-40582 is a high-severity vulnerability identified in Siemens SCALANCE LPE9403 devices, specifically those with the SINEMA Remote Connect Edge Client installed. The vulnerability is classified as CWE-78, which corresponds to improper neutralization of special elements used in an OS command, commonly known as OS command injection. The root cause is the failure of the affected devices to properly sanitize configuration parameters. This flaw allows a non-privileged local attacker to inject and execute arbitrary commands with root privileges on the device. Given the nature of the vulnerability, an attacker with local access—either physical or via a compromised local account—can escalate privileges and execute commands that compromise the confidentiality, integrity, and availability of the device and potentially the network it supports. The CVSS v3.1 base score is 7.8, indicating a high severity level, with the vector AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H, meaning the attack requires local access and low complexity, with low privileges but no user interaction, and impacts confidentiality, integrity, and availability at a high level. Siemens SCALANCE LPE9403 devices are industrial network components used in critical infrastructure and industrial automation environments, often deployed in manufacturing, energy, and transportation sectors. The SINEMA Remote Connect Edge Client facilitates remote management and connectivity, making these devices strategic points in operational technology (OT) networks. The absence of known exploits in the wild suggests this vulnerability is newly disclosed, but the potential impact is significant due to root-level command execution capabilities. The lack of available patches at the time of disclosure increases the urgency for mitigation and monitoring.

Potential Impact

For European organizations, especially those operating in critical infrastructure sectors such as manufacturing, energy, transportation, and industrial automation, this vulnerability poses a significant risk. Exploitation could lead to unauthorized control over network edge devices, enabling attackers to disrupt operations, manipulate industrial processes, or pivot deeper into OT and IT networks. The ability to execute root commands can result in data theft, sabotage, or persistent backdoors, undermining operational continuity and safety. Given the strategic importance of Siemens SCALANCE devices in European industrial environments, successful exploitation could have cascading effects on supply chains and essential services. Additionally, regulatory frameworks such as NIS2 and GDPR impose strict requirements on securing critical infrastructure and protecting data, meaning exploitation could also lead to legal and compliance consequences for affected organizations.

Mitigation Recommendations

1. Immediate Network Segmentation: Isolate SCALANCE LPE9403 devices from general IT networks and restrict local access to trusted personnel only. 2. Access Control Hardening: Enforce strict local access policies, including strong authentication mechanisms and monitoring of local user activities. 3. Configuration Parameter Validation: Until a patch is available, implement compensating controls such as input validation proxies or wrappers that sanitize configuration inputs before they reach the device. 4. Monitoring and Logging: Enable detailed logging on affected devices and monitor for unusual command executions or privilege escalations. 5. Incident Response Preparedness: Develop and rehearse response plans specific to OT device compromise scenarios. 6. Vendor Engagement: Maintain close communication with Siemens for timely patch releases and apply updates as soon as they become available. 7. Physical Security: Enhance physical security controls to prevent unauthorized local access to devices. 8. Network Access Controls: Use firewalls and intrusion detection/prevention systems to limit and monitor traffic to and from these devices, focusing on local access vectors.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2025-04-16T08:20:17.032Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d9816c4522896dcbd65fa

Added to database: 5/21/2025, 9:08:38 AM

Last enriched: 7/12/2025, 2:16:28 AM

Last updated: 8/18/2025, 12:48:48 AM

Views: 14

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats