Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2025-43942: CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Dell Unity

0
High
VulnerabilityCVE-2025-43942cvecve-2025-43942cwe-78
Published: Thu Oct 30 2025 (10/30/2025, 14:23:26 UTC)
Source: CVE Database V5
Vendor/Project: Dell
Product: Unity

Description

CVE-2025-43942 is a high-severity OS command injection vulnerability affecting Dell Unity versions 5. 5 and prior. It allows a low-privileged local attacker to execute arbitrary OS commands due to improper neutralization of special elements in input. Exploitation can lead to full command execution and privilege escalation without requiring user interaction. The vulnerability impacts confidentiality, integrity, and availability of affected systems. No known exploits are currently in the wild. European organizations using Dell Unity storage solutions are at risk, especially those with local access policies that could be exploited. Mitigations include applying vendor patches once available, restricting local access, and implementing strict input validation. Countries with significant Dell Unity deployments and critical infrastructure relying on such storage systems are most likely affected. The CVSS score of 7.

AI-Powered Analysis

AILast updated: 10/30/2025, 14:56:00 UTC

Technical Analysis

CVE-2025-43942 is an OS command injection vulnerability classified under CWE-78, found in Dell Unity storage systems version 5.5 and earlier. The flaw arises from improper neutralization of special characters in inputs that are passed to operating system commands. This allows a low-privileged attacker with local access to inject and execute arbitrary commands on the underlying OS. Because the vulnerability does not require user interaction and can lead to privilege escalation, it poses a significant threat to system security. The attacker could leverage this to compromise system confidentiality by accessing sensitive data, integrity by modifying or deleting data, and availability by disrupting system operations. The CVSS 3.1 score of 7.8 indicates high severity with attack vector local, low attack complexity, low privileges required, no user interaction, and full impact on confidentiality, integrity, and availability. No public exploits have been reported yet, but the vulnerability is publicly disclosed and should be considered a critical risk for affected environments. The lack of patch links suggests that remediation may still be pending or in progress from Dell. Organizations using Dell Unity should prioritize mitigation to prevent potential exploitation.

Potential Impact

For European organizations, this vulnerability could lead to severe operational disruptions and data breaches, especially in sectors relying heavily on Dell Unity storage arrays such as finance, healthcare, telecommunications, and government. The ability for a low-privileged local attacker to escalate privileges and execute arbitrary commands could result in unauthorized access to sensitive data, manipulation or destruction of critical information, and potential downtime of storage services. This could have cascading effects on business continuity and regulatory compliance, including GDPR implications due to potential data exposure. The threat is particularly concerning for organizations with less restrictive local access controls or those that allow multiple users with local system access. Given Dell Unity's deployment in enterprise storage environments, the scope of impact could be broad, affecting data centers and cloud service providers across Europe.

Mitigation Recommendations

1. Monitor Dell’s official security advisories closely and apply patches or firmware updates as soon as they are released to address CVE-2025-43942. 2. Restrict local access to Dell Unity systems strictly to trusted administrators and enforce the principle of least privilege. 3. Implement robust input validation and sanitization controls on any interfaces or scripts interacting with the storage system to prevent injection of malicious commands. 4. Use host-based intrusion detection systems (HIDS) to monitor for unusual command execution or privilege escalation attempts on storage nodes. 5. Conduct regular security audits and penetration testing focused on local access vectors to identify and remediate potential exploitation paths. 6. Employ network segmentation to isolate storage management interfaces from general user networks, reducing the risk of unauthorized local access. 7. Maintain comprehensive logging and alerting for command execution and administrative actions on Dell Unity devices to enable rapid detection and response.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.2
Assigner Short Name
dell
Date Reserved
2025-04-20T05:04:01.416Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 690378f1aebfcd547472f154

Added to database: 10/30/2025, 2:40:49 PM

Last enriched: 10/30/2025, 2:56:00 PM

Last updated: 10/30/2025, 3:49:10 PM

Views: 2

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats