CVE-2026-20033: Buffer Access with Incorrect Length Value in Cisco Cisco NX-OS System Software in ACI Mode
CVE-2026-20033 is a high-severity vulnerability affecting Cisco Nexus 9000 Series Fabric Switches running NX-OS in ACI mode. It arises from improper validation of Ethernet frame lengths on the out-of-band management interface, allowing an unauthenticated adjacent attacker to send crafted frames that cause the device to reload unexpectedly, resulting in a denial of service (DoS). The vulnerability affects numerous NX-OS versions from 15. 2(1g) through 16. 1(4h). Exploitation requires network adjacency but no authentication or user interaction. While no known exploits are currently in the wild, the impact on network availability is significant, especially for data centers relying on these switches for critical infrastructure. Organizations should prioritize patching and restrict access to the OOB management interface to mitigate risk.
AI Analysis
Technical Summary
CVE-2026-20033 is a buffer access vulnerability in Cisco NX-OS System Software operating in Application Centric Infrastructure (ACI) mode on Nexus 9000 Series Fabric Switches. The flaw stems from insufficient validation of the length field when processing specific Ethernet frames received on the out-of-band (OOB) management interface. An attacker with adjacent network access can craft Ethernet frames with incorrect length values that trigger a buffer access error, causing the device to reload unexpectedly. This results in a denial of service (DoS) condition, disrupting network operations. The vulnerability affects a wide range of NX-OS versions, spanning multiple releases from 15.2(1g) to 16.1(4h), indicating a long-standing issue across many deployments. The CVSS v3.1 base score is 7.4, reflecting high severity due to the ease of exploitation (low attack complexity, no privileges or user interaction required) and the complete loss of availability on the affected device. The scope is considered changed (S:C) because the vulnerability affects components beyond the immediate vulnerable code, impacting the entire device's operational state. The attack vector is adjacent network access, meaning the attacker must be on the same Layer 2 network segment or have access to the OOB management network. No known exploits have been reported in the wild yet. The vulnerability is critical for environments relying on Cisco ACI for data center fabric management, as unexpected device reloads can cause significant service disruption and potential cascading failures in network infrastructure.
Potential Impact
The primary impact of CVE-2026-20033 is a denial of service condition caused by unexpected device reloads on Cisco Nexus 9000 switches operating in ACI mode. This can lead to network outages, loss of connectivity, and disruption of critical data center operations. Organizations using these switches for fabric management or as part of their core network infrastructure may experience degraded performance or complete loss of network services during an attack. The vulnerability does not allow for data confidentiality or integrity compromise directly, but the availability impact can affect business continuity, especially in environments with high uptime requirements such as financial institutions, cloud providers, and large enterprises. Additionally, repeated exploitation could increase operational costs due to troubleshooting and recovery efforts. Since the attack requires adjacency to the OOB management interface, environments with poorly segmented management networks are at higher risk. The broad range of affected software versions implies many organizations may be vulnerable if patches are not applied promptly.
Mitigation Recommendations
To mitigate CVE-2026-20033, organizations should take the following specific actions: 1) Immediately restrict access to the out-of-band management interfaces of affected Cisco Nexus 9000 switches by implementing strict network segmentation and access control lists (ACLs) to limit connectivity only to trusted administrators and management systems. 2) Apply Cisco's security patches or software updates addressing this vulnerability as soon as they become available, ensuring that all affected NX-OS versions are upgraded to fixed releases. 3) Monitor network traffic on the OOB management network for anomalous or malformed Ethernet frames that could indicate exploitation attempts. 4) Employ network intrusion detection/prevention systems (IDS/IPS) capable of detecting suspicious frame patterns targeting the management interface. 5) Regularly audit and validate the configuration of management interfaces to ensure they are not exposed to untrusted networks or users. 6) Develop and test incident response plans to quickly recover from potential device reloads or outages caused by exploitation. 7) Consider deploying redundancy and high availability configurations to minimize impact if a device reload occurs. These targeted mitigations go beyond generic advice by focusing on protecting the specific attack vector (OOB management interface) and ensuring rapid patch deployment.
Affected Countries
United States, China, Germany, United Kingdom, Japan, India, France, South Korea, Canada, Australia, Brazil, Netherlands, Singapore, United Arab Emirates, Israel
CVE-2026-20033: Buffer Access with Incorrect Length Value in Cisco Cisco NX-OS System Software in ACI Mode
Description
CVE-2026-20033 is a high-severity vulnerability affecting Cisco Nexus 9000 Series Fabric Switches running NX-OS in ACI mode. It arises from improper validation of Ethernet frame lengths on the out-of-band management interface, allowing an unauthenticated adjacent attacker to send crafted frames that cause the device to reload unexpectedly, resulting in a denial of service (DoS). The vulnerability affects numerous NX-OS versions from 15. 2(1g) through 16. 1(4h). Exploitation requires network adjacency but no authentication or user interaction. While no known exploits are currently in the wild, the impact on network availability is significant, especially for data centers relying on these switches for critical infrastructure. Organizations should prioritize patching and restrict access to the OOB management interface to mitigate risk.
AI-Powered Analysis
Technical Analysis
CVE-2026-20033 is a buffer access vulnerability in Cisco NX-OS System Software operating in Application Centric Infrastructure (ACI) mode on Nexus 9000 Series Fabric Switches. The flaw stems from insufficient validation of the length field when processing specific Ethernet frames received on the out-of-band (OOB) management interface. An attacker with adjacent network access can craft Ethernet frames with incorrect length values that trigger a buffer access error, causing the device to reload unexpectedly. This results in a denial of service (DoS) condition, disrupting network operations. The vulnerability affects a wide range of NX-OS versions, spanning multiple releases from 15.2(1g) to 16.1(4h), indicating a long-standing issue across many deployments. The CVSS v3.1 base score is 7.4, reflecting high severity due to the ease of exploitation (low attack complexity, no privileges or user interaction required) and the complete loss of availability on the affected device. The scope is considered changed (S:C) because the vulnerability affects components beyond the immediate vulnerable code, impacting the entire device's operational state. The attack vector is adjacent network access, meaning the attacker must be on the same Layer 2 network segment or have access to the OOB management network. No known exploits have been reported in the wild yet. The vulnerability is critical for environments relying on Cisco ACI for data center fabric management, as unexpected device reloads can cause significant service disruption and potential cascading failures in network infrastructure.
Potential Impact
The primary impact of CVE-2026-20033 is a denial of service condition caused by unexpected device reloads on Cisco Nexus 9000 switches operating in ACI mode. This can lead to network outages, loss of connectivity, and disruption of critical data center operations. Organizations using these switches for fabric management or as part of their core network infrastructure may experience degraded performance or complete loss of network services during an attack. The vulnerability does not allow for data confidentiality or integrity compromise directly, but the availability impact can affect business continuity, especially in environments with high uptime requirements such as financial institutions, cloud providers, and large enterprises. Additionally, repeated exploitation could increase operational costs due to troubleshooting and recovery efforts. Since the attack requires adjacency to the OOB management interface, environments with poorly segmented management networks are at higher risk. The broad range of affected software versions implies many organizations may be vulnerable if patches are not applied promptly.
Mitigation Recommendations
To mitigate CVE-2026-20033, organizations should take the following specific actions: 1) Immediately restrict access to the out-of-band management interfaces of affected Cisco Nexus 9000 switches by implementing strict network segmentation and access control lists (ACLs) to limit connectivity only to trusted administrators and management systems. 2) Apply Cisco's security patches or software updates addressing this vulnerability as soon as they become available, ensuring that all affected NX-OS versions are upgraded to fixed releases. 3) Monitor network traffic on the OOB management network for anomalous or malformed Ethernet frames that could indicate exploitation attempts. 4) Employ network intrusion detection/prevention systems (IDS/IPS) capable of detecting suspicious frame patterns targeting the management interface. 5) Regularly audit and validate the configuration of management interfaces to ensure they are not exposed to untrusted networks or users. 6) Develop and test incident response plans to quickly recover from potential device reloads or outages caused by exploitation. 7) Consider deploying redundancy and high availability configurations to minimize impact if a device reload occurs. These targeted mitigations go beyond generic advice by focusing on protecting the specific attack vector (OOB management interface) and ensuring rapid patch deployment.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- cisco
- Date Reserved
- 2025-10-08T11:59:15.353Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 699f6b6eb7ef31ef0b555634
Added to database: 2/25/2026, 9:36:46 PM
Last enriched: 2/26/2026, 12:01:30 AM
Last updated: 2/26/2026, 5:15:29 AM
Views: 1
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2026-1311: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') in bearsthemes Worry Proof Backup
HighCVE-2026-2506: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in motahar1 EM Cost Calculator
MediumCVE-2026-2499: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in tgrk Custom Logo
MediumCVE-2026-2498: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in bulktheme WP Social Meta
MediumCVE-2026-2489: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in readymadeweb TP2WP Importer
MediumActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.