Skip to main content
VulnerabilityPublished

CVE-2026-20033: Cisco NX-OS System Software in ACI Mode · Buffer Access with Incorrect Length Value

Affects Cisco NX-OS System Software in ACI ModeSource CVE Database V5

0
Compare

Not known to be exploited · CVSS 7.4 High.

Data as of 29 Oct 2026, 19:04 UTC

CVSS 3.1 base score
7.4High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.1% chance of exploitation in 30 days – higher than 6% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 25 Feb 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 29 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
CiscoCisco NX-OS System Software in ACI ModeAffected
  • 15.2(1g) – 16.1(4h)
57 affected builds
Fixed in–

AI-suggested

To mitigate CVE-2026-20033, organizations should take the following specific actions: 1) Immediately restrict access to the out-of-band management interfaces of affected Cisco Nexus 9000 switches by implementing strict network segmentation and access control lists (ACLs) to limit connectivity only to trusted administrators and management systems. 2) Apply Cisco's security patches or software updates addressing this vulnerability as soon as they become available, ensuring that all affected NX-OS versions are upgraded to fixed releases. 3) Monitor network traffic on the OOB management network for anomalous or malformed Ethernet frames that could indicate exploitation attempts. 4) Employ network intrusion detection/prevention systems (IDS/IPS) capable of detecting suspicious frame patterns targeting the management interface. 5) Regularly audit and validate the configuration of management interfaces to ensure they are not exposed to untrusted networks or users. 6) Develop and test incident response plans to quickly recover from potential device reloads or outages caused by exploitation. 7) Consider deploying redundancy and high availability configurations to minimize impact if a device reload occurs. These targeted mitigations go beyond generic advice by focusing on protecting the specific attack vector (OOB management interface) and ensuring rapid patch deployment.

Description

A vulnerability in Cisco Nexus 9000 Series Fabric Switches in ACI mode could allow an unauthenticated, adjacent attacker to cause a denial of service (DoS) condition on an affected device. This vulnerability is due to insufficient validation when processing specific Ethernet frames. An attacker could exploit this vulnerability by sending a crafted Ethernet frame to the management interface of an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition. Note: Only the out-of-band (OOB) management interface is affected.

References

Community reviews