Skip to main content
VulnerabilityPublished Updated

CVE-2026-4551: Tenda F453 · Stack-based Buffer Overflow

Affects Tenda F453Source CVE Database V5

0
Compare

Public exploit available · CVSS 8.7 High.

Data as of 30 Oct 2026, 11:52 UTC

CVSS 4.0 base score
8.7High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.6% chance of exploitation in 30 days – higher than 50% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 22 Mar 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: evidence found.

    CVSS exploit maturity: proof of concept public

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), CVSS vector, the Metasploit, Exploit-DB and nuclei-templates index as of 30 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
TendaF453Affected
  • =1.0.0.3
Fixed in–
GitHubtenda/F453pkg:github/tenda/F453Other threatsAffected
  • =1.0.0.3
Fixed in–

Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.

AI-suggested

To mitigate CVE-2026-4551, organizations should immediately verify if their Tenda F453 devices are running firmware version 1.0.0.3 and prioritize upgrading to a patched firmware version once released by the vendor. In the absence of an official patch, temporary mitigations include disabling remote management interfaces to reduce exposure to external attackers and restricting access to the /goform/SafeClientFilter endpoint via firewall rules or network segmentation. Network administrators should monitor logs and network traffic for unusual requests targeting the vulnerable parameter 'menufacturer/Go'. Implementing intrusion detection or prevention systems with signatures for this exploit can help detect and block attempts. Additionally, isolating vulnerable devices from critical network segments limits potential lateral movement. Users should change default credentials and ensure strong authentication mechanisms are in place for device management. Regularly reviewing vendor advisories and subscribing to vulnerability notifications will help maintain timely awareness of updates. Finally, organizations should consider replacing outdated or unsupported devices with models that receive ongoing security updates.

Description

CVE-2026-4551 is a high-severity stack-based buffer overflow vulnerability affecting Tenda F453 routers running firmware version 1.0.0.3. The flaw exists in the fromSafeClientFilter function within the /goform/SafeClientFilter component, where manipulation of the 'menufacturer/Go' argument can trigger the overflow. This vulnerability can be exploited remotely without authentication or user interaction, enabling attackers to potentially execute arbitrary code or cause denial of service. Although no public exploit is currently observed in the wild, a proof-of-concept exploit has been made public, increasing the risk of exploitation. The vulnerability impacts confidentiality, integrity, and availability due to the possibility of full system compromise. Organizations using affected Tenda F453 devices should prioritize patching or mitigating this issue. Countries with significant deployment of Tenda networking equipment, especially in Asia and emerging markets, are at higher risk.

References