Skip to main content
CVE-2024-22082VulnerabilityPublished Updated

CVE-2024-22082: n/a

Source CVE Database V5

0

Not known to be exploited · CVSS 7.5 High.

Data as of 26 Oct 2026, 06:26 UTC

CVSS 3.1 base score
7.5High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.6% chance of exploitation in 30 days – higher than 50% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 20 Mar 2024

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.

What to do

AI-suggested

To mitigate CVE-2024-22082, organizations should implement the following specific measures: 1) Restrict network access to the Elspec G5 web interface by placing devices behind firewalls or network segmentation controls, limiting access only to authorized personnel and management networks. 2) Employ VPNs or secure management channels to access the device interface, preventing exposure to the public internet. 3) Monitor network traffic and device logs for unusual directory listing requests or reconnaissance activity targeting the web interface. 4) Disable or restrict directory listing functionality on the device if configurable, or apply web server configuration changes to prevent directory enumeration. 5) Engage with the vendor to obtain firmware updates or patches addressing this vulnerability as soon as they become available. 6) Conduct regular security assessments and penetration tests focusing on device web interfaces and management portals. 7) Implement strict access control policies and multi-factor authentication for device management where supported to reduce risk of unauthorized access. 8) Maintain an inventory of all Elspec G5 devices and ensure they are included in vulnerability management programs. These targeted actions go beyond generic advice by focusing on network-level controls, monitoring, and vendor engagement specific to this device and vulnerability.

Description

An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. Unauthenticated directory listing can occur: the web interface cay be abused be an attacker get a better understanding of the operating system.

References

Community reviews