A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0). The affected application contains a vulnerability in its firmware update mechanism's signature validation process. This could allow an attacker to install malicious firmware, leading to persistent code execution and system compromise.
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0). The affected application includes a debugging interface that is accessible through HTTP endpoints. This could allow an authenticated attacker to disrupt the system by crashing the web process causing denial of service conditions.
A vulnerability has been identified in Mendix Studio Pro 10.11 (All versions), Mendix Studio Pro 10.12 (All versions), Mendix Studio Pro 10.13 (All versions), Mendix Studio Pro 10.14 (All versions), Mendix Studio Pro 10.15 (All versions), Mendix Studio Pro 10.16 (All versions), Mendix Studio Pro 10.17 (All versions), Mendix Studio Pro 10.18 (All versions), Mendix Studio Pro 10.19 (All versions), Mendix Studio Pro 10.20 (All versions), Mendix Studio Pro 10.21 (All versions), Mendix Studio Pro 10.22 (All versions), Mendix Studio Pro 10.23 (All versions), Mendix Studio Pro 10.24 (All versions < V10.24.21), Mendix Studio Pro 11.0 (All versions), Mendix Studio Pro 11.1 (All versions), Mendix Studio Pro 11.10 (All versions), Mendix Studio Pro 11.11 (All versions), Mendix Studio Pro 11.2 (All versions), Mendix Studio Pro 11.3 (All versions), Mendix Studio Pro 11.4 (All versions), Mendix Studio Pro 11.5 (All versions), Mendix Studio Pro 11.6 (All versions < V11.6.7), Mendix Studio Pro 11.7 (All versions), Mendix Studio Pro 11.8 (All versions), Mendix Studio Pro 11.9 (All versions). Affected versions of Mendix Studio Pro do not properly validate or sanitize project files processed during the build pipeline.
This could allow an attacker who tricks a user into opening and running a specially crafted malicious project locally on their system to execute arbitrary code in the context of that user.
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application uses a password hashing implementation with a static, hardcoded salt shared across all users and installations, and is configured with an insufficient number of iterations. This could allow an attacker to efficiently recover user passwords using brute-force or precomputed attacks, potentially resulting in unauthorized access.
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected system includes a binary that is configured with the cap_dac_override capability. This capability allows the process to bypass file system permission checks, resulting in unrestricted file system access. This could allow a local attacker to escalate privileges leading to arbitrary file modification and gaining root privileges on the system.
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application does not properly sanitize path input in the `GET /api/sftp/uploadFiles` endpoint used for directory listing. This allows path traversal through crafted input, enabling access to unintended file system locations.
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The application does not properly sanitize user input in the /api/sftp/uploadFiles endpoint, allowing the injection of shell command payloads via crafted directory names. These payloads are stored and executed when directory listings are retrieved. This could allow an authenticated remote attacker to execute arbitrary commands on the underlying operating system with the privileges of the affected service user (sinecins).
A vulnerability has been identified in SIMATIC WinCC Unified PC Runtime V16 (All versions), SIMATIC WinCC Unified PC Runtime V17 (All versions), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions), SIMATIC WinCC Unified PC Runtime V20 (All versions), SIMATIC WinCC Unified PC Runtime V21 (All versions < V21 Update 2). Insufficient protection of key material in WinCC Certificate Manager that could allow an attacker to extract sensitive information.
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V4.0). The affected applications stores sensitive information in the browser cache when an authenticated user modify specific configurations. This could allow an authenticated attacker to access sensitive data stored in the browser.
CVE-2026-42177 is an improper access control vulnerability in the Siemens linux-entra-sso browser plugin for Linux versions prior to 1.8.1. The vulnerability arises because the Chrome adapter registers a broad URL matching rule that attaches the Entra ID Primary Refresh Token (PRT) cookie to requests matching a substring pattern, without properly restricting the URL scope. This can cause the PRT cookie to be sent to attacker-controlled hosts if the URL path embeds the legitimate login URL, potentially exposing sensitive authentication tokens. The issue is fixed in version 1.8.1.
Siemens Simcenter Femap contains a memory corruption vulnerability while parsing specially crafted IPT files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2026 (All versions < V226.0 Update 5). The affected applications contain a stack based overflow vulnerability while parsing specially crafted PAR files.
This could allow an attacker to execute code in the context of the current process.
CVE-2026-44411 is a high-severity vulnerability in Siemens Solid Edge SE2026 versions prior to V226.0 Update 5. It involves access of an uninitialized pointer during parsing of specially crafted PAR files. Successful exploitation could allow an attacker to execute code with the privileges of the current process. There is no confirmed patch or official remediation available at this time. No known exploits are reported in the wild.
CVE-2026-41551 is a critical relative path traversal vulnerability in Siemens ROS# versions prior to 2.2.2. The issue arises from improper sanitization of user input, allowing remote attackers to access arbitrary files on affected devices. The vulnerability has a high CVSS score of 9.1, indicating significant confidentiality and integrity impact without requiring privileges or user interaction. No official patch or remediation guidance is currently confirmed from the vendor. There are no known exploits in the wild at this time.
CVE-2026-33893 is a high-severity vulnerability in Siemens Teamcenter versions prior to certain patch levels across multiple releases. The issue involves hardcoded cryptographic keys embedded in the application for obfuscation purposes. An attacker who obtains these keys could misuse them to gain unauthorized access. There is no official patch or remediation level currently indicated by the vendor. The vulnerability has a CVSS score of 7.5, reflecting its network exploitable nature and high confidentiality impact without requiring privileges or user interaction.
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page.
Affected devices do not properly restrict access to the web browser via the Control Panel when no corresponding security mechanisms are in place.
This could allow an unauthenticated attacker to gain unauthorized access to the web browser, potentially enabling the discovery of backdoors, performing unauthorized actions, or exploiting misconfigurations that may lead to further system compromise.
Affected devices do not properly validate and sanitize filenames on the Firmware Update page. This could allow a remote attacker to social engineer the user into selecting the modified firmware file to be uploaded. This would result in malitcious JavaScript execution in the context of the authenticated user's session without requiring the file to be uploaded, potentially leading to session hijacking or credential theft.